English
Language : 

M24C64-FDW5TP Datasheet, PDF (23/45 Pages) STMicroelectronics – 64-Kbit serial I²C bus EEPROM
M24C64-W M24C64-R M24C64-F
8
DC and AC parameters
This section summarizes the operating and measurement conditions, and the DC and AC
characteristics of the device.
Table 6. Operating conditions (voltage range W)
Symbol
Parameter
Min.
Max.
VCC
Supply voltage
TA
Ambient operating temperature
fC
Operating clock frequency
1. fCmax is 400 kHz devices identified by process letter P.
2.5
5.5
–40
85
-
1(1)
Unit
V
°C
MHz
Table 7. Operating conditions (voltage range R)
Symbol
Parameter
Min.
Max.
VCC
Supply voltage
TA
Ambient operating temperature
fC
Operating clock frequency
1. fCmax is 400 kHz devices identified by process letter P.
1.8
5.5
–40
85
-
1(1)
Unit
V
°C
MHz
Table 8. Operating conditions (voltage range F)
Symbol
Parameter
Min.
Max.
Unit
VCC Supply voltage
1.6(1)
1.7
5.5
V
Ambient operating temperature:READ
-40
-40
85
TA
Ambient operating temperature: WRITE
0
-40
85
°C
Operating clock frequency @1.6 V(1)
fC
Operating clock frequency @1.7 V
-
400
kHz
-
1000
1. Only for devices identified with process letter T
DocID16891 Rev 30
23/45
44