English
Language : 

CLP200M Datasheet, PDF (14/21 Pages) STMicroelectronics – OVERVOLTAGE AND OVERCURRENT PROTECTION FOR TELECOM LINE
CLP200M
TEST CIRCUIT FOR ISWOFF PARAMETER : GO-NO GO TEST
R
VBAT = - 48 V
D.U.T.
- VP
Surge
generator
This is a GO-NO GO test which allows to confirm the switch-off (ISWOFF) level in a functional test circuit.
TEST PROCEDURE :
- Adjust the current level at the ISWOFF value by short circuiting the D.U.T.
- Fire the D.U.T. with a surge current : IPP = 10A, 10/1000µs.
- The D.U.T. will come back to the OFF-state within a duration of 50ms max.
Fig. 29 : Typical variation of switching-on current
(positive or negative) versus RSENSE resistor and
junction temperature (see test condition Fig 31).
ISWON (mA)
500
-20°C 25°C 75°C
300
200
Fig. 30 : Variation of switching-on current versus
RSENSE at 25°C.
Iswon @ 25°C (mA)
500
Iswon min
negative
Iswon max
negative
Iswon min
posi tive
Iswon min
positive
300
200
100
3
5
7
Rsense (Ω)
9 11 13
100
3
5
7
Rsense (Ω)
9 11
Fig. 31 : ISWON MEASUREMENT
- Iswon = I1 when the CLP200M switches on (I1 is
progressively increased using R)
- Both TIP and RING sides of the CLP200M are
checked
- RL = 10 Ω.
RL
R sense
I1
± 48 V
TIPL TIPS
R
DUT GND
RINGL RINGS
Fig. 32 : Relative variation of switching-off current
versus junction temperature for RSENSE between 3
and 10 Ω.
ISWOFF [Tj°C] / ISWOFF [25°C]
2.0
1.8
1.6
1.4
1.2
1.0
0.8
0.6
0.4
-40 -20
0
20 40 60 80
Tj (°C)
14/21
®