English
Language : 

OA1MPA Datasheet, PDF (11/28 Pages) STMicroelectronics – Medical instrumentation
OA1MPA, OA2MPA, OA4MPA
Electrical characteristics
Symbol
Table 6. Electrical characteristics (continued)
Parameter
Conditions
Min. Typ. Max. Unit
ICC
Supply current (per channel, T = 25 °C
Vout = VCC/2, RL > 1 M)
-40 °C < T< 125 °C
10 14
µA
16
AC performance
GBP
Fu
Fm
Gm
SR
en
Gain bandwidth product
Unity gain frequency
Phase margin
Gain margin
Slew rate(5)
Low-frequency peak-to-peak
input noise
RL = 10 k, CL = 100 pF
RL = 10 k, CL = 100 pF,
Vout = 0.5 V to VCC - 0.5 V
Bandwidth: f = 0.1 to 10 Hz
110 150
120
45
19
0.06
10
kHz
Degrees
dB
V/s
µVpp
f = 1 kHz
en
Equivalent input noise voltage
f = 10 kHz
100
---n---V-----
96
Hz
THD+N
Total harmonic distortion +
noise
tinit
Initialization time(6)
fin = 1 kHz, ACL = 1,
RL = 100 k, Vicm = (VCC - 1 V)/2,
BW = 22 kHz, Vout = 0.5 Vpp
T = 25 °C
-40 °C < T< 125 °C
0.008
%
5
ms
50
1. See Section 4.4: Input offset voltage drift over temperature.
2. Typical value is based on the Vio drift observed after 1000h at 125 °C extrapolated to 25 °C using the Arrhenius law and
assuming an activation energy of 0.7 eV. The operational amplifier is aged in follower mode configuration. See Section 4.5:
Long-term input offset voltage drift.
3. Guaranteed by characterization.
4. Tested on SC70-5 package.
5. Slew rate value is calculated as the average between positive and negative slew rates.
6. Initialization time is defined as the delay after power-up to guarantee operation within specified performances. Guaranteed
by design. See Section 4.6: Initialization time.
DocID025992 Rev 1
11/28