BIT
BIT NAME
7 Reset
6 Command
Chaining Enable
5 Transmit Enable
4,3 Extended
Timeout 1,2
2 Backplane
1,0 Sub Address 1,0
Table 6.9 - Configuration Register
SYMBOL
RESET
CCHEN
TXEN
ET1, ET2
DESCRIPTION
A software reset of the COM20020ID is executed by writing a logic
"1" to this bit. A software reset does not reset the microcontroller
interface mode, nor does it affect the Configuration Register. The
only registers that the software reset affect are the Status Register,
the Next ID Register, and the Diagnostic Status Register. This bit
must be brought back to logic "0" to release the reset.
This bit, if high, enables the Command Chaining operation of the
device. Please refer to the Command Chaining section for further
details. A low level on this bit ensures software compatibility with
previous SMSC ARCNET devices.
When low, this bit disables transmissions by keeping nPULSE1,
nPULSE2 if in non-Backplane Mode, and nTXEN pin inactive.
When high, it enables the above signals to be activated during
transmissions. This bit defaults low upon reset. This bit is typically
enabled once the Node ID is determined, and never disabled during
normal operation. Please refer to the Improved Diagnostics section
for details on evaluating network activity.
These bits allow the network to operate over longer distances than
the default maximum 2 miles by controlling the Response, Idle, and
Reconfiguration Times. All nodes should be configured with the
same timeout values for proper network operation. For the
COM20020ID with a 20 MHz crystal oscillator, the bit combinations
follow:
Reconfig
Response Idle Time Time (mS)
ET2
ET1
Time (μS) (μS)
840
0
0
596.6
656
840
0
1
298.4
328
840
1
0
149.2
164
420
1
1
37.4
41
Note: These values are for 5Mbps and RCNTMR[1,0]=00.
Reconfiguration time is changed by the RCNTMR1 and
RCNTMR0 bits.
BACK-
PLANE
SUBAD 1,0
A logic "1" on this bit puts the device into Backplane Mode signaling
which is used for Open Drain and Differential Driver interfaces.
These bits determine which register at address 07 may be
accessed. The combinations are as follows:
SUBAD1
SUBAD0
Register
0
0
Tentative ID
0
1
Node ID
1
0
Setup 1
1
1
Next ID
See also the Sub Address Register.
SMSC COM20020I Rev D
Page 35
DATASHEET
Revision 12-05-06