English
Language : 

COM20019I_06 Datasheet, PDF (33/65 Pages) SMSC Corporation – Low Cost ARCNET (ANSI 878.1) Controller with 2K x 8 On-Board RAM
Low Cost ARCNET (ANSI 878.1) Controller with 2K x 8 On-Board RAM
BIT
BIT NAME
3,2,1 Clock Prescaler
Bits 3,2,1
0
Slow Arbitration
Select
SYMBOL
CKP3,2,1
SLOWARB
DESCRIPTION
These bits are used to determine the data rate of the
COM20019I. The following table is for a 20 MHz crystal:
CKP3 CKP2 CKP1 DIVISOR SPEED
0
1
1
64
312.5 Kbs
1
0
0
128
156.25 Kbs
Note: The lowest data rate achievable by the COM20019I
is 156.25 Kbs. Defaults to 011 or 312.5 Kbps.
This bit, when set, will divide the arbitration clock by 2.
Memory cycle times will increase when slow arbitration is
selected.
Defaults to low.
BIT
7
BIT NAME
Read Bus Timing
Select
6,5,4 Reserved
3
Enhanced
Functions
2
No Synchronous
1,0 Reconfiguration
Timer 1, 0
Table 6.11 - Setup 2 Register
SYMBOL
DESCRIPTION
RBUSTMG This bit is used to Disable/Enable the High Speed CPU
Read function for High Speed CPU bus support.
RBUSTMG=0: Disable (Default), RBUSTMG=1: Enable. It
does not influence write operation. High speed CPU Read
operation is only for non-multiplexed bus.
These bits are undefined.
EF
This bit is used to enable the new enhanced functions in the
COM20019I. EF = 0: Disable (Default), EF = 1: Enable. If
EF = 0, the timing and function is the same as in the
COM20020, Revision B. See appendix “A”. EF bit must be
‘1’ if the data rate is over 5Mbps.
EF bit should be ‘1’ for new design customers.
EF bit should be ‘0’ for replacement customers.
NOSYNC
This bit is used to enable the SYNC command during
initialization. NOSYNC= 0, Enable (Default) The line must
be idle for the RAM initialization sequence to be written.
NOSYNC= 1, Disable:) The line does not have to be idle for
the RAM initialization sequence to be written. See appendix
“A”.
RCNTM1,
0
These bits are used to program the reconfiguration timer as
a function of maximum node count. These bits set the time
out period of the reconfiguration timer as shown below. The
time out periods shown are for 312.5 Kbps.
RCNTM1 RCNTM0 Time Out
Period
Max Node Count
0
0
6.72 S
Up to 255 nodes
0
1
1.68 S
Up to 64 nodes
1
0
840 mS
Up to 32 nodes
1
1
420 mS*
Up to 16 nodes
Note*: The node ID value 255 must exist in the network for
420 mS timeout to be valid.
SMSC COM20019I
Page 33
DATASHEET