SKY73208-11 Datasheet, PDF (7/17 Pages) Skyworks Solutions Inc. – 350-5000 MHz Wideband Receive Mixer with Integrated Integer-N PLL and VCO
DATA SHEET • SKY73208-11: MIXER WITH PLL AND VCO
24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
0 11 0 0 0 0 1 1 x x x x x x x x x x x x x x 0 0
4-Bit Device
Address
5-Bit Register
Address
MSBs of 18-Bit
N-Divider Value
Note: Value of bits [15:2] can vary. Refer to the Skyworks Wideband, Integer-N Phase-Locked Loop Programming Guide, document number 201322.
S1848b
Figure 7. N_DIV2 Register Showing an N-Divider Value of 4500 (MSBs)
Electrical and Mechanical Specifications
The absolute maximum ratings of the SKY73208-11 are
provided in Table 3. The recommended operating conditions are
specified in Table 4 and electrical specifications are provided in
Table 5.
Table 3. SKY73208-11 Absolute Maximum Ratings (Note 1)
Parameter
Symbol
Minimum
Typical
Maximum
Units
Mixer supply voltage (VDD_LO, VDD_IF, VDD_MIXBIAS, and VDD_MIX = +5 V) VDD_MIX
5.5
V
Synthesizer supply voltage (VDD_VCO, VDD_OBUF, VDD_PLL, VDD_CLK,
VDD_DIV, VDD_CP, and VDD_DIG = +3.3 V)
VDD_SYNTH
3.6
V
Mixer supply current (VDD_LO, VDD_IF, VDD_MIXBIAS, and VDD_MIX = +5 V) IDD_MIX
200
mA
Synthesizer supply current (VDD_VCO, VDD_OBUF, VDD_PLL, VDD_CLK,
VDD_DIV, VDD_CP, and VDD_DIG = +3.3 V)
IDD_SYNTH
150
mA
RF input power
PIN
+10
dBm
Operating case temperature
TC
–40
+85
C
Junction temperature
TJ
+150
C
Storage case temperature
TSTG
–40
+125
C
Notes: Exposure to maximum rating conditions for extended periods may reduce device reliability. There is no damage to device with only one parameter set at the limit and all other
parameters set at or below their nominal value. Exceeding any of the limits listed here may result in permanent damage to the device.
CAUTION: Although this device is designed to be as robust as possible, electrostatic discharge (ESD) can damage this device. This device
must be protected at all times from ESD. Static charges may easily produce potentials of several kilovolts on the human body
or equipment, which can discharge without detection. Industry-standard ESD precautions should be used at all times.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
201317F • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • November 5, 2015
7