SKYA21052 Datasheet, PDF (5/21 Pages) Skyworks Solutions Inc. – 0.7 to 2.7 GHz SP12T MIPI Antenna Switch Module | |||
|
◁ |
DATA SHEET ⢠SKYA21052: SP12T ANTENNA SWITCH WITH MIPI INTERFACE
Table 4. SKYA21052 RF Electrical Specifications1 (2 of 2)
(VDD = 2.85 V, TOP = +25 ï°C, Characteristic Impedance [ZO] = 50 Ω, Unless Otherwise Noted)
Parameter
Symbol
Test Condition
Min
Typical
Max
TRx 1, 2, 7, 8, 9, 10 ports to
TRx 3, 4, 5, 6 ports:
824 to 1910 MHz
1910 to 2690 MHz
32
35
25
30
Tx LB to any TRx/Rx ports:
824 to 960 MHz
35
36
Tx HB to any TRx/Rx ports:
1710 to 1910 MHz
30
32
Isolation
Any adjacent ports:
ISO
824 to1910 MHz
1910 to 2690 MHz
20
23
17
19
Any non-adjacent ports:
824 to1910 MHz
1910 to 2690MHz
25
28
20
23
Antenna to any TRx ports:
824 to1910 MHz
1910 to 2690 MHz
30
31.5
23
26
Tx LB to Tx HB when TX HB is on:
1648 to 1830 MHz
27
28.5
Return loss
|S11|
0.7 to 2.7 GHz
14
18
GSM harmonics:
2fo, 3fo
High band
PIN = +33 dBm, 50 Ω
PIN = +33 dBm, 3:1 VSWR
â53
â40
â41
Low band
PIN = +35 dBm, 50 Ω
PIN = +35 dBm, 3:1 VSWR
â50
â45
â36
TRXx harmonics
2fo, 3fo
PIN = +27 dBm, 50 Ω,
f = 704 to 2700 MHz
PIN = +27 dBm, 5:1 VSWR,
f = 704 to 2700 MHz
â68
â62
â58
â50
TRX1 through TRX10,
2fo
PIN = +25 dBm
band 13 2nd harmonics
f = 787 MHz
â81
Second order intermodulation distortion IMD2
See test conditions in Table 5
â110
â105
Third order intermodulation distortion
IMD3
See test conditions in Table 6
â110
â105
Triple Beat Ratio:
650 to 900 MHz
1710 to 2155 MHz
TBR
See test conditions in Table 7
+81
+81
Turn-on time
tON
From application of VDD and VIO
20
Switching speed
tS
Port to port
1 Performance is guaranteed only under the conditions listed in this table.
2
5
Units
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dBm
dBm
dBm
dBm
dBm
dBm
dBm
dBm
dBm
dBc
dBc
μs
μs
Skyworks Solutions, Inc. ⢠Phone [781] 376-3000 ⢠Fax [781] 376-3100 ⢠sales@skyworksinc.com ⢠www.skyworksinc.com
204040C ⢠Skyworks Proprietary Information ⢠Products and Product Information are Subject to Change Without Notice ⢠January 17, 2017
5
|
▷ |