SKY66104-11 Datasheet, PDF (4/14 Pages) Skyworks Solutions Inc. – 1787 to 1930 MHz High-Power RF Front-End Module | |||
|
◁ |
DATA SHEET ⢠SKY66104-11: HIGH-POWER RF FEM
Table 5. SKY66104-11 Transmit Mode Electrical Specifications (Note 1) (Note 2)
(VCC1/2 = +3.6 V, VDD = 3.6 V, TC = +25 ï°C, PIN = 0 dBm, as Measured on the SKY66104-11 Evaluation Board (De-Embedded to Device),
All Used and Unused Ports Terminated with 50 Ω, Unless Otherwise Noted)
Parameter
Symbol
Test Condition
Min
Typical
Max
Units
Frequency range (Note 3)
f
1880
1930
MHz
Output power at ANT1/2 ports (Note 4)
POUT
NTP ⥠1.55 V
+24
dBm
NTP ⤠0.3 V
+0
dBm
Output power variation over temperature
POUT_TV
TC = â40 ï°C to +85 ï°C,
(Note 4) (Note 5)
relative to the value at
25 ï°C
â2
â0.9/+0.8
+2
dB
NTP input voltage (Note 4)
NTP
POUT = +15 dB
0.7
V
POUT = +10 dB
0.5
V
Small signal gain
S21
PIN = â25 dBm,
NTP = 1.8 V
+27
dB
TX-RX port isolation
S21TX-RX
Pin 13 relative to pin 18
5
dB
AntâRX port isolation
S21ANT-RX
Pin 13 relative to pin 5 or 7
29
dB
Input return loss
S11
@ TX port
â12
â7
dB
Output return loss
S22
â12
â8
dB
1 dB output compression point (Note 6)
OP1dB
NTP = 1.8 V
+24
dBm
2nd and 3rd harmonics
2fo, 3fo
NTP = 1.8 V, CW
â50
â30
dBc
Higher harmonics (Note 5)
4fo to 10 fo NTP = 1.8 V, CW
â50
â40
dBc
Turn-on time (Note 5)
tON
From 50% of rising logic
control to 90% of final RF
output power
1.6
5
μs
Turn-off time (Note 5)
tOFF
From 50% of falling logic
control to 10% of final RF
output power
0.3
5
μs
Stability (Note 5)
Stab
NTP = 1.8 V, CW
f = 0.1 GHz to 20 GHz,
load VSWR = 6:1
All non-harmonically related outputs < â40 dBm
Ruggedness (Note 5)
RU
NTP = 1.8 V, CW
load VSWR = 6:1
No permanent damage
Note 1: Performance is guaranteed only under the conditions listed in this Table. Production testing is performed at 1905 MHz. Transmit (TX) Mode configuration is defined in Table 9. Typical
performance shown is for Engineering Sample 2 (ES2).
Note 2: With specified matching network between pins PA_OUT and OMN_SW. POUT measured at ANT1/ANT2 ports.
Note 3: f = 1787 MHz to 1880 MHz at reduced performance with POUT = +20 dBm.
Note 4: NTP is an analog input control. See Figure 3 for typical characteristics.
Note 5: Not tested in production. Fully characterized and guaranteed by design.
Note 6: Starting point for test is PIN = â13 dBm.
Skyworks Solutions, Inc. ⢠Phone [781] 376-3000 ⢠Fax [781] 376-3100 ⢠sales@skyworksinc.com ⢠www.skyworksinc.com
4
December 9, 2014 ⢠Skyworks Proprietary Information ⢠Products and Product Information are Subject to Change Without Notice ⢠202908C
|
▷ |