English
Language : 

SKY66115-11_17 Datasheet, PDF (3/12 Pages) Skyworks Solutions Inc. – 400 to 510 MHz Front-End Module for Range Extension Applications
DATA SHEET • SKY66115-11: 400 TO 510 MHz FEM
Table 3. SKY66115-11 Recommended Operating Conditions
Frequency1
Parameter
Symbol
f
Supply voltages
VCC, VDD
Control voltages
VCSD, VCTX
Digital input voltage (CSD and CTX):
Logic 0
Logic 1
1 Below 470 MHz, an external harmonic filter is required.
VLOW
VHIGH
Min
Typ
Max
Units
400
510
MHz
2.5
3.3
3.6
V
0
VDD
V
0
0.45
V
2.8
VDD
V
Table 4. SKY66115-11 Electrical Specifications: DC Characteristics1
(VCC = VDD = 3.3 V, TA= +25 °C, No RF Input Power, Unless Otherwise Noted)
Parameter
Symbol
Test Condition
Rx current
ICQ_RX_VDD
Rx Mode
Tx quiescent current, VDD
ICQ_TX_VDD
Tx Mode
Tx quiescent current, VCC
ICQ_TX_VCC
Tx Mode
Tx operating current
IOP_TX_VCC
Tx Mode, POUT = +20 dBm
Sleep current, VDD
IDD_OFF
Sleep Mode
Sleep current, VCC
ICC_OFF
Sleep Mode
Digital input current, logic 02
ILOW
Sleep Mode
Digital input current, logic 12
IHIGH
Sleep Mode
1 Performance is guaranteed only under the conditions listed in this table.
2 Not production tested.
Min
Typ
Max
Units
3
A
5
mA
40
mA
67
mA
3
A
0.04
1
A
0
A
33
A
Table 5. SKY66115-11 Electrical Specifications: Transmit Characteristics1
(VCC = VDD = 3.3 V, TA= +25 °C, POUT = +20 dBm, 470 to 510 MHz, Characteristic Impedance [Zo] = 50 Ω, Unless Otherwise Noted)
Parameter
Symbol
Test Condition
Min
Typ
Max
Units
Input power
PIN_20dBm
4
dBm
TX small signal gain
|S21|
PIN = –25 dBm
18
dB
Input return loss
|S11|
8
dB
Output return loss
|S22|
10
dB
ANT to Rx isolation
ISO_ANT_TO_RX
2nd to 10th harmonics2
2fo to 10fo
POUT = +20 dBm:
< 1 GHz
> 1 GHz
Rx to Tx transition time3
tSWITCH
50% VCTX to 90% RF
Tx Power on time3
tON
50% VCSD to 90% RF
Tx Power off time3
tOFF
50% VCSD to 10% RF
Non-harmonic spurious3
PSPUR
VSWR 6:1, all phases
1 Performance is guaranteed only under the conditions listed in this table.
2 2nd to 5th harmonics are production tested. 6th to 10th harmonics are characterized only.
3 Not production tested.
35
dB
–36
dBm
–30
dBm
0.6
s
0.1
s
0.1
s
–42
dBm
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
203309G • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • January 11, 2017
3