English
Language : 

SKY66112-11_17 Datasheet, PDF (2/14 Pages) Skyworks Solutions Inc. – 2.4 GHz ZigBee/Thread/Bluetooth Smart Front-End Module
DATA SHEET • SKY66112-11: ZIGBEE/THREAD/BLUETOOTH SMART FEM
Table 1. SKY66112-11 Signal Descriptions1
Pin
Name
Description
1 GND
Ground
2 CRX
Connect to GPIO signal for mode control (see Table 6)
3 CSD
Connect to GPIO signal for mode control (see Table 6)
4 ANT_SEL
Connect to GPIO signal to control antenna switch
(see Table 7)
5 GND
Ground
6 ANT2
Connect to 50 Ω antenna
7 GND
Ground
8 ANT1
Connect to 50 Ω antenna
9 GND
Ground
10 GND
Ground
11 VDD
Digital logic and RF switch supply
1 The paddle should be connected to ground.
Pin
Name
12 GND
13 GND
14 VCC2
15 CPS
16 VCC1
17 CTX
18 GND
19 CHL
20 GND
21 RFIN
22 GND
Description
Ground
Ground
PA output stage supply
Connect to GPIO signal for mode control (see Table 6)
PA first stage and LNA supply
Connect to GPIO signal for mode control (see Table 6)
Ground
Connect to GPIO signal for mode control (see Table 6)
Ground
RF input power (transmit/receive port)
Ground
Electrical and Mechanical Specifications
The absolute maximum ratings of the SKY66112-11 are provided
in Table 2. The recommended operating conditions are specified
in Table 3, and electrical specifications are provided in Tables 4
and 5.
The state of the SKY66112-11 is determined by the logic provided
in Table 6. Table 7 shows the antenna select logic.
Table 2. SKY66112-11 Absolute Maximum Ratings1
Parameter
Symbol
Minimum
Maximum
Units
Supply voltage
VCC1
–0.3
+3.6
V
VCC2
–0.3
+3.6
V
VDD
–0.3
+3.6
V
Control pin voltages
Transmit output power at ANT1 or ANT2 port into 50 Ω load
Transmit input power at RFIN port
Receive input power at ANT1 or ANT2 ports2
Bypass input power at ANT1 or ANT2 ports2
Operating temperature
Storage temperature
VCTL
POUT_TX_MAX
PIN_TX_MAX
PIN_RX_MAX
PIN_BYP_MAX
TA
TSTG
–0.3
+3.6
V
+22.5
dBm
+5.0
dBm
+15
dBm
+20
dBm
–40
+85
C
–40
+125
C
Electrostatic discharge:
ESD
Human Body Model (HBM)
3000
V
1 Exposure to maximum rating conditions for extended periods may reduce device reliability. There is no damage to device with only one parameter set at the limit and all other parameters set
at or below their nominal value. Exceeding any of the limits listed here may result in permanent damage to the device.
2 CW test signal.
ESD HANDLING: Although this device is designed to be as robust as possible, electrostatic discharge (ESD) can damage this device.
This device must be protected at all times from ESD when handling or transporting. Static charges may easily produce
potentials of several kilovolts on the human body or equipment, which can discharge without detection.
Industry-standard ESD handling precautions should be used at all times.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
2
March 14, 2017 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 203225L