English
Language : 

SKY66111-11 Datasheet, PDF (2/14 Pages) Skyworks Solutions Inc. – Low-Power Bluetooth Low Energy Front-End Module for Range Extension Applications
DATA SHEET • SKY66111-11: LOW-POWER BLUETOOTH LOW ENERGY FEM
Table 1. SKY66111-11 Signal Descriptions1
Pin
Name
Description
1
GND
Ground
2
GND
Ground
3
GND
Ground
4
TR
Common receive/transmit port
5
GND
Ground
6
GND
Ground
7
GND
Ground
8
GND
Ground
9
GND
Ground
10 GND
Ground
1 The paddle should be connected to ground. See Figure 6.
Electrical and Mechanical Specifications
The absolute maximum ratings of the SKY66111-11 are provided
in Table 2. The recommended operating conditions are specified
in Table 3.
Pin
Name
Description
11
ANT
Antenna port
12
GND
Ground
13
GND
Ground
14
VCC
Positive power supply
15
GND
Ground
16
GND
Ground
17
CRX
RX control signal
18
GND
Ground
19
CTX
Tx control signal
20
BIAS
PA bias current input, connect to CTX through a resistor
Electrical specifications are provided in Tables 4 through 8.
Table 2. SKY66111-11 Absolute Maximum Ratings1
Parameter
Symbol
Minimum
Maximum
Units
Supply voltage
VCC
5.5
V
Control voltages
VCTX, VCRX
5.0
V
Bias voltage
VBIAS
5.0
V
RF Input power
PIN
+20
dBm
Voltage standing wave ratio
VSWR
10:1
Operating temperature
TA
–40
+85
°C
Storage temperature
TSTG
–65
+150
°C
Electrostatic discharge:
ESD
Human Body Model (HBM), Class 0
150
V
1 Exposure to maximum rating conditions for extended periods may reduce device reliability. There is no damage to device with only one parameter set at the limit and all other parameters set
at or below their nominal value. Exceeding any of the limits listed here may result in permanent damage to the device.
CAUTION: Although this device is designed to be as robust as possible, electrostatic discharge (ESD) can damage this device. This device
must be protected at all times from ESD. Static charges may easily produce potentials of several kilovolts on the human body
or equipment, which can discharge without detection. Industry-standard ESD precautions should be used at all times.
Table 3. Recommended Operating Conditions
Parameter
Symbol
Frequency
f
Supply voltage
VCC
Control voltages
VCTX, VCRX
Bias voltage
VBIAS
Operating temperature
TA
Minimum
2.4
1.8
1.7
1.25
Typical
3
3
1.8
25
Maximum
2.485
5.0
VCC
VCC
Units
GHz
V
V
V
°C
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
2
February 22, 2016 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 203199E