English
Language : 

SKY13498-21 Datasheet, PDF (14/21 Pages) Skyworks Solutions Inc. – 0.7 to 2.7 GHz SP10T MIPI Antenna Switch Module
DATA SHEET • SKY13498-21: SP10T ANTENNA SWITCH WITH MIPI INTERFACE
Table 13. Register Description and Programming (2 of 3)
Register
Name
Address
(Hex)
Parameter
Reserved
GROUP_SID
001B GSID
PWR_MODE
Trigger_Mask_2
PM_TRIG
(Note 1)
Trigger_Mask_1
001C
Trigger_Mask_0
Trigger_2
Trigger_1
Trigger_0
PRODUCT_ID
001D PRODUCT_ID
Description
Bits[7:4]: Reserved
Bits[3:0]:
Group slave ID
Bits[7:6]:
00 = Normal operation (active)
01 = Default settings (startup)
10 = Low power (low power)
11 = Reserved
Bit[5]:
If this bit is set, trigger 2 is disabled. When all triggers are disabled, if
writing to a register that is associated with trigger 2, the data goes
directly to the destination register.
Bit[4]:
If this bit is set, trigger 1 is disabled. When all triggers are disabled, if
writing to a register that is associated with trigger 1, the data goes
directly to the destination register.
Bit[3]:
If this bit is set, trigger 0 is disabled. When all triggers are disabled, if
writing to a register that is associated with trigger 0, the data goes
directly to the destination register.
Bit[2]:
If this bit is set, data is loaded into the trigger 2 registers.
Bit[1]:
If this bit is set, data is loaded into the trigger 1 registers
(unsupported).
Bit[0]:
If this bit is set, data is loaded into the trigger 0 registers
(unsupported).
Bits[7:0]:
This is a read–only register. However, during the programming of the
Unique Slave Identifier (USID), a write command sequence is
performed on this register but the value is not changed.
Default
(Binary)
0000
0000
00
0
0
0
0
0
0
01011111
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
14
April 23, 2014 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 202807E