SI7013 Datasheet, PDF (9/43 Pages) Silicon Laboratories – I2C HUMIDITY AND TWO-ZONE TEMPERATURE SENSOR | |||
|
◁ |
Si7013
Table 5. Temperature Sensor
1.9 ⤠VDD ⤠3.6 V; TA = â40 to +85 °C (G grade) or â40 to +125 °C (I/Y grade), default conversion time unless otherwise noted.
Parameter
Operating Range
Accuracy1
Repeatability-Noise
Response Time2
Long Term Stability
Symbol
Ï63%
Test Condition
I and Y Grade
G Grade
â10 °C < tA < 85 °C
â40 °C < tA < 125 °C
14-bit resolution
13-bit resolution
12-bit resolution
11-bit resolution
Unmounted device
Si7013-EB board
Min Typ Max
â40
â +125
â40
â
+85
â ±0.3 ±0.4
Figure 3
â 0.01 â
â 0.02 â
â 0.04 â
â 0.08 â
â
0.7
â
â
5.1
â
â < 0.01 â
Unit
°C
°C
°C
°C
°C RMS
°C RMS
°C RMS
°C RMS
s
s
°C/Yr
Notes:
1. 14b measurement resolution (default).
2. Time to reach 63% of final value in response to a step change in temperature. Actual response time will vary
dependent on system thermal mass and airflow.
Figure 3. Temperature Accuracy*
*Note: Applies only to I and Y devices beyond +85 °C.
Rev. 0.95
9
|
▷ |