English
Language : 

SI7013 Datasheet, PDF (11/43 Pages) Silicon Laboratories – I2C HUMIDITY AND TWO-ZONE TEMPERATURE SENSOR
Si7013
Table 7. Thermal Characteristics
Parameter
Junction to Air Thermal Resistance
Junction to Air Thermal Resistance
Junction to Air Thermal Resistance
Junction to Case Thermal Resistance
Junction to Board Thermal Resistance
Symbol
JA
JA
JA
JC
JB
Test Condition
JEDEC 2-Layer board,
No Airflow
JEDEC 2-Layer board,
1 m/s Airflow
JEDEC 2-Layer board,
2.5 m/s Airflow
JEDEC 2-Layer board
JEDEC 2-Layer board
DFN-6
236
203
191
20
112
Unit
°C/W
°C/W
°C/W
°C/W
°C/W
Table 8. Absolute Maximum Ratings1
Parameter
Symbol
Test Condition
Min Typ
Max
Unit
Ambient temperature
under bias
–55
—
125
°C
Storage
TemperatureFigure 2
–65
—
150
°C
Voltage on I/O pins
–0.3 — VDD+0.3V V
Voltage on VDD with
respect to GND
–0.3 —
4.2
V
Notes:
1. Absolute maximum ratings are stress ratings only, operation at or beyond these conditions is not implied and may
shorten the life of the device or alter its performance.
2. Special handling considerations apply; see application note, “AN607: Si70xx Humidity Sensor Designer’s Guide” for
details.
Rev. 0.95
11