3.3 Optional Dynamic Signal Demonstration
Note: Logic inputs should NOT exceed the respective VDD.
UG130: Si86xxT-EVB User's Guide
Hardware Setup and Demonstration
For an example, see the figure below.
⢠Remove all shunts.
⢠Setup signal generator and oscilloscope.
⢠Generate 0 V to VDD1 peak, square wave (up to 300 MHz, but within the oscilloscopeâs capabilities) on the signal generator.
⢠Split the signal generator output to two separate BNC cables via the splitter.
⢠Attach one BNC cable end to oscilloscope Channel 1 and configure the channel for 1x gain.
⢠Attach the 10x oscilloscope probe to oscilloscope channel 2 configure the channel for 10x gain.
⢠Connect the remaining BNC cable end to the BNC-to-test-clip adapter.
⢠Clip the signal generatorâs output to A2 relative to GND1 (via either TP5 or TP3).
⢠Clip the oscilloscope probeâs signal line on B1 and reference to GND2 (via either TP4 or TP6).
⢠Observe Channel 1 (input â A2) and Channel 2 (output â B2) on the oscilloscope for various parametrics such as skew and jitter.
Figure 3.5. EVB Configured for Dynamic Signal Demonstration without Enable