English
Language : 

S-93L46A Datasheet, PDF (9/48 Pages) Seiko Instruments Inc – LOW VOLTAGE OPERATION CMOS SERIAL E2PROM
Rev.3.1_00
LOW VOLTAGE OPERATION CMOS SERIAL E2PROM
S-93L46A/56A/66A
„ AC Electrical Characteristics
Table 17 Measurement Conditions
Input pulse voltage
0.1 × VCC to 0.9 × VCC
Output reference voltage
0.5 × VCC
Output load
100 pF
Table 18
Parameter
Symbol VCC = 4.5 to 5.5 V VCC = 2.5 to 4.5 V VCC = 1.6 to 2.5 V Unit
Min. Typ. Max. Min. Typ. Max. Min. Typ. Max.
CS setup time
CS hold time
CS deselect time
Data setup time
Data hold time
Output delay time
Clock frequency*1
SK clock time “L” *1
SK clock time “H” *1
Output disable time
Output enable time
tCSS
0.2
tCSH
0
tCDS
0.2
tDS
0.1
tDH
0.1
tPD
—
fSK
0
tSKL
0.1
tSKH
0.1
tHZ1, tHZ2 0
tSV
0
— — 0.4 —
—— 0 —
— — 0.2 —
— — 0.2 —
— — 0.2 —
— 0.4 — —
— 2.0 0 —
— — 0.25 —
— — 0.25 —
— 0.15 0 —
— 0.15 0 —
— 1.0
—0
— 0.4
— 0.4
— 0.4
0.8 —
1.0 0
— 1.0
— 1.0
0.5 0
0.5 0
— — µs
— — µs
— — µs
— — µs
— — µs
— 2.0 µs
— 0.25 MHz
— — µs
— — µs
— 1.0 µs
— 1.0 µs
*1. The clock cycle of the SK clock (frequency: fSK) is 1/fSK µs. This clock cycle is determined by a
combination of several AC characteristics, so be aware that even if the SK clock cycle time is
minimized, the clock cycle (1/fSK) cannot be made equal to tSKL(Min.) + tSKH(Min.).
Parameter
Write time
Table 19
Symbol
VCC = 1.8 to 5.5 V
Unit
Min
Typ.
Max.
tPR
—
4.0
8.0
ms
Seiko Instruments Inc.