English
Language : 

S-5841A55D-M5T1X Datasheet, PDF (8/26 Pages) Seiko Instruments Inc – TEMPERATURE SWITCH IC
TEMPERATURE SWITCH IC (THERMOSTAT IC)
S-5841 Series
Rev.2.2_01
 DC Electrical Characteristics
1. CMOS output product
1. 1 SOT-23-5
Table 7
(Ta = +25°C, unless otherwise specified)
Item
Symbol
Condition
Min.
Typ. Max.
Unit
Test
circuit
Power supply voltage*1
Detection temperature
VDD
TDET = +55°C to +100°C
TDET = +40°C to +54°C
2.2
−
10.0
V
1
2.6
−
10.0
V
1
+TD
−
TDET − 2.5 TDET TDET + 2.5 °C
1
Hysteresis option
HYS1
−
−
−
−
−
Hysteresis of detection
temperature*2
THYS
A
B
"H"
−
2
−
°C
1
"L"
−
10
−
°C
1
"H"
−
4
−
°C
1
"L"
−
10
−
°C
1
Output current
Current consumption
during operation
IDETH VDD = 3.0 V,
VDET = 2.2 V
2
9.4
−
mA 2
IDETL apply to DET pin VDET = 0.4 V
0.5
2.3
−
mA 2
IDD
VDD = 3.0 V
−
10
20
μA
1
HYS1 pin input voltage "H" VIH1
HYS1 pin input voltage "L" VIL1
HYS1 pin input current "H" IIH1
HYS1 pin input current "L" IIL1
−
−
VDD = 3.0 V, VHYS1 = 3.0 V
VDD = 3.0 V, VHYS1 = 0 V
0.8 × VDD −
−
V
3
−
− 0.2 × VDD V
3
−0.1
−
0.1
μA
3
−0.1
−
0.1
μA
3
*1. The minimum operation voltages are as follows under the operation ambient temperature over +100°C.
VDD = 2.3 V min. (Detection temperature = +55°C to +100°C)
VDD = 2.7 V min. (Detection temperature = +40°C to +54°C)
*2. The hysteresis temperature can be set by the HYS1 pin.
These two types are selectable by option.
Hysteresis option A: 2°C of hysteresis temperature during HYS1 = "H",
10°C of hysteresis temperature during HYS1 = "L"
Hysteresis option B: 4°C of hysteresis temperature during HYS1 = "H",
10°C of hysteresis temperature during HYS1 = "L"
[Fahrenheit ⇔ Celsius Conversion equation]
°C = (°F − 32) × 5 / 9
°F = 32 + °C × 9 / 5
8