S-5841A55D-M5T1X Datasheet, PDF (10/26 Pages) Seiko Instruments Inc – TEMPERATURE SWITCH IC | |||
|
◁ |
TEMPERATURE SWITCH IC (THERMOSTAT IC)
S-5841 Series
Rev.2.2_01
2. Nch open drain output
2. 1 SOT-23-5
Table 9
(Ta = +25°C, unless otherwise specified)
Item
Symbol
Condition
Min.
Typ.
Max.
Unit
Test
circuit
Power supply voltage*1
Detection temperature
VDD
TDET = +55°C to +100°C
TDET = +40°C to +54°C
2.2
â
10.0
V
1
2.6
â
10.0
V
1
+TD
â
TDET â 2.5 TDET TDET + 2.5 °C
1
Hysteresis option
HYS1
â
â
â
â
â
Hysteresis of detection
temperature*2
THYS
A
B
"H"
â
2
â
°C
1
"L"
â
10
â
°C
1
"H"
â
4
â
°C
1
"L"
â
10
â
°C
1
Output current
Leakage current
Current consumption
during operation
IDETL
ILEAK
IDD
VDET = 0.4 V, VDD = 3.0 V
VDET = 10.0 V, VDD = 3.0 V
VDD = 3.0 V
0.5
2.3
â
mA 2
â
â
100
nA
2
â
10
20
μA
1
HYS1 pin input voltage "H" VIH1
HYS1 pin input voltage "L" VIL1
HYS1 pin input current "H" IIH1
HYS1 pin input current "L" IIL1
â
â
VDD = 3.0 V, VHYS1 = 3.0 V
VDD = 3.0 V, VHYS1 = 0 V
0.8 Ã VDD â
â
V
3
â
â 0.2 Ã VDD V
3
â0.1
â
0.1
μA
3
â0.1
â
0.1
μA
3
*1. The minimum operation voltages are as follows under the operation ambient temperature over +100°C.
VDD = 2.3 V min. (Detection temperature = +55°C to +100°C)
VDD = 2.7 V min. (Detection temperature = +40°C to +54°C)
*2. The hysteresis temperature can be set by the HYS1 pin.
These two types are selectable by option.
Hysteresis option A: 2°C of hysteresis temperature during HYS1 = "H",
10°C of hysteresis temperature during HYS1 = "L"
Hysteresis option B: 4°C of hysteresis temperature during HYS1 = "H",
10°C of hysteresis temperature during HYS1 = "L"
[Fahrenheit â Celsius Conversion equation]
°C = (°F â 32) à 5 / 9
°F = 32 + °C à 9 / 5