English
Language : 

S-5841A55D-M5T1X Datasheet, PDF (11/26 Pages) Seiko Instruments Inc – TEMPERATURE SWITCH IC
Rev.2.2_01
TEMPERATURE SWITCH IC (THERMOSTAT IC)
S-5841 Series
2. 2 SNT-6A
Table 10
(Ta = +25°C, unless otherwise specified)
Item
Symbol
Condition
Min.
Typ.
Max.
Unit
Test
circuit
Power supply voltage*1
Detection temperature
VDD
TDET = +55°C to +100°C
TDET = +40°C to +54°C
2.2
−
10.0
V
1
2.6
−
10.0
V
1
+TD
−
TDET − 2.5 TDET TDET + 2.5 °C
1
HYS1
HYS2
−
−
−
−
−
Hysteresis of detection
temperature*2
THYS
"H"
"H"
"L"
"H"
−
2
−
°C
1
"L"
−
4
−
°C
1
"H"
−
10
−
°C
1
"L"
"L"
−
0
−
°C
1
Output current
Leakage current
Current consumption
during operation
IDETL
ILEAK
IDD
VDET = 0.4 V, VDD = 3.0 V
VDET = 10.0 V, VDD = 3.0 V
VDD = 3.0 V
0.5
2.3
−
mA 2
−
−
100
nA
2
−
10
20
μA
1
HYS1 pin input voltage "H" VIH1
HYS1 pin input voltage "L" VIL1
HYS1 pin input current "H" IIH1
HYS1 pin input current "L" IIL1
HYS2 pin input voltage "H" VIH2
HYS2 pin input voltage "L" VIL2
HYS2 pin input current "H" IIH2
HYS2 pin input current "L" IIL2
−
−
VDD = 3.0 V, VHYS1 = 3.0 V
VDD = 3.0 V, VHYS1 = 0 V
−
−
VDD = 3.0 V, VHYS2 = 3.0 V
VDD = 3.0 V, VHYS2 = 0 V
0.8 × VDD −
−
V
3
−
− 0.2 × VDD V
3
−0.1
−
0.1
μA
3
−0.1
−
0.1
μA
3
0.8 × VDD −
−
V
3
−
− 0.2 × VDD V
3
−0.1
−
0.1
μA
3
−0.1
−
0.1
μA
3
*1. The minimum operation voltages are as follows under the operation ambient temperature over +100°C.
VDD = 2.3 V min. (Detection temperature = +55°C to +100°C)
VDD = 2.7 V min. (Detection temperature = +40°C to +54°C)
*2. The hysteresis temperature can be switched in 0°C, 2°C, 4°C, 10°C, and is set by the HYS1 pin and HYS2 pin.
[Fahrenheit ⇔ Celsius Conversion equation]
°C = (°F − 32) × 5 / 9
°F = 32 + °C × 9 / 5
 AC Electrical Characteristics
Table 11
Item
Noise suppression time
Symbol
Condition
tdelay
VDD = 3.0 V,
Ta = detection temperature
Min.
Typ.
Max.
Unit
Test
circuit
−
380
−
μs
−
11