English
Language : 

S-5711A Datasheet, PDF (7/26 Pages) Seiko Instruments Inc – HALL IC
Rev.2.4_00
HALL IC
S-5711A Series
„ Magnetic Characteristics
1. Product with detection of both poles
Table 7
Item
Operating point*1
Release point*2
Hysteresis width*3
S pole
N pole
S pole
N pole
S pole
N pole
Symbol
BOPS
BOPN
BRPS
BRPN
BHYSS
BHYSN
(Ta = 25°C, VDD = 3.0 V, VSS = 0 V unless otherwise specified)
Conditions
Test
Min.
Typ.
Max.
Unit Circuit
−
−
3.8
6.0
mT
3
−
−6.0
−3.8
−
mT
3
−
0.5
2.8
−
mT
3
−
−
−2.8
−0.5
mT
3
BHYSS = BOPS − BRPS
BHYSN = |BOPN − BRPN|
−
1.0
−
mT
3
−
1.0
−
mT
3
2. Product with detection of south pole
Table 8
Item
Operating point*1
Release point*2
Hysteresis width*3
S pole
S pole
S pole
Symbol
BOPS
BRPS
BHYSS
(Ta = 25°C, VDD = 3.0 V, VSS = 0 V unless otherwise specified)
Conditions
Min.
Typ.
Max.
Unit
Test
Circuit
−
−
3.8
6.0
mT
3
−
0.5
2.8
−
mT
3
BHYSS = BOPS − BRPS
−
1.0
−
mT
3
3. Product with detection of north pole*4
Table 9
Item
Operating point*1
Release point*2
Hysteresis width*3
N pole
N pole
N pole
Symbol
BOPN
BRPN
BHYSN
(Ta = 25°C, VDD = 3.0 V, VSS = 0 V unless otherwise specified)
Conditions
Min.
Typ.
Max.
Unit
Test
Circuit
−
−6.0
−3.8
−
mT
3
−
−
−2.8
−0.5
mT
3
BHYSN = |BOPN − BRPN|
−
1.0
−
mT
3
*1. BOPN, BOPS : Operating points
The operating points are the values of magnetic flux density when the output voltage (VOUT) is inverted after the magnetic
flux density applied to the S-5711A Series by the magnet (N or S pole) is increased (the magnet is moved closer).
Even when the magnetic flux density exceeds BOPN or BOPS, VOUT retains the status.
*2. BRPN, BRPS : Release points
The release points are the values of magnetic flux density when the output voltage (VOUT) is inverted after the magnetic
flux density applied to the S-5711A Series by the magnet (N or S pole) is decreased (the magnet is moved further away).
Even when the magnetic flux density falls below BRPN or BRPS, VOUT retains the status.
*3. BHYSN, BHYSS : Hysteresis widths
BHYSN and BHYSS are the difference between BOPN and BRPN, and BOPS and BRPS, respectively.
*4. Selectable by option
Remark The unit of magnetic density mT can be converted by using the formula 1 mT = 10 Gauss.
Seiko Instruments Inc.
7