S-5711A Series
2. Basic operation
The S-5711A Series changes the output voltage level (VOUT) according to the level of the magnetic flux density (north
or south pole) applied by a magnet.
The following explains the operation when the magnetism detection logic is active âLâ.
(1) Products with detection of both poles
When the magnetic flux density vertical to the marking surface exceeds BOPN or BOPS after the south or north pole
of a magnet is moved closer to the marking surface of the S-5711A Series, VOUT changes from âHâ to âLâ. When
the south or north pole of a magnet is moved further away from the marking surface of the S-5711A Series and
the magnetic flux density is lower than BRPN or BRPS, VOUT changes from âLâ to âHâ.
(2) Products with detection of south pole
When the magnetic flux density vertical to the marking surface exceeds BOPS after the south pole of a magnet is
moved closer to the marking surface of the S-5711A Series, VOUT changes from âHâ to âLâ. When the south pole
of a magnet is moved further away from the marking surface of the S-5711A Series and the magnetic flux density
is lower than BRPS, VOUT changes from âLâ to âHâ.
(3) Products with detection of north pole*1
When the magnetic flux density vertical to the marking surface exceeds BOPN after the north pole of a magnet is
moved closer to the marking surface of the S-5711A Series, VOUT changes from âHâ to âLâ. When the north pole
of a magnet is moved further away from the marking surface of the S-5711A Series and the magnetic flux density
is lower than BRPN, VOUT changes from âLâ to âHâ.
*1. Selectable by option
Seiko Instruments Inc.
11
|
▷ |