English
Language : 

S-24CM01C Datasheet, PDF (7/32 Pages) Seiko Instruments Inc – Write protect function during the low power supply voltage
Rev.2.0_02_S
2-WIRE SERIAL E2PROM
S-24CM01C
Item
Write time
Table 12
Ta = −40°C to +85°C
Symbol
VCC = 1.7 V to 5.5 V
Unit
Min.
Max.
tWR
−
5.0
ms
Start Condition
Write data
Acknowledgment
Signal
Stop Condition
tWR
Start Condition
SCL
SDA
tWS1
WP
(valid)
WP
tWS2
(invalid)
D0
tWH1
tWH2
Figure 5 Write Cycle Timing
7