English
Language : 

S-5470A21I-M5T1U Datasheet, PDF (6/24 Pages) Seiko Instruments Inc – ULTRA-LOW CURRENT CONSUMPTION
ULTRA-LOW CURRENT CONSUMPTION NORMALLY-OFF FAINT SIGNAL DETECTION IC
S-5470 Series
Rev.1.3_01
 Electrical Characteristics
Item
Power supply voltage
Current consumption
Detection current
Release current
Detection current
temperature coefficient
Input current
Current amplifier current
amplification ratio × 2
Source current
Sink current
Output response time
Table 5
Symbol
Condition
VDD
Ta = −40°C to +85°C
IDD
VINP = VSS, VINM = VSS
VINP = 1.0 V, VINM = VSS
IDET
−
IREL
−
(Ta = +25°C, VDD = 3.0 V unless otherwise specified)
Min.
Typ. Max.
Unit
Test
Circuit
0.9
−
5.5
V
−
−
0.01 10
nA
1
−
0.02 10
nA
1
0.52 0.7 0.88 nA
2
IDET × IDET × IDET ×
0.7 0.8 0.9
nA
2
Itc
IINP
IINM
GINM
Ta = −40°C to +85°C
VINP = 1.0 V
VINM = 1.0 V
−
−
±0.5
−
%/°C
−
20
−
−
μA
3
10
−
−
μA
3
1.8
2.0
2.2 Times
4
ISOURCE
CMOS output product VDD = 0.9 V
VOUT = VDD − 0.3 V
VDD = 3.0 V
0.01
3.5
0.4
4.8
−
−
mA
mA
5
5
ISINK
VOUT = 0.3 V
VDD = 0.9 V 0.5
1.7
−
mA
6
VDD = 3.0 V 7.0
9.2
−
mA
6
tOD
−
−
−
15
ms
−
6