English
Language : 

S-5470A21I-M5T1U Datasheet, PDF (11/24 Pages) Seiko Instruments Inc – ULTRA-LOW CURRENT CONSUMPTION
ULTRA-LOW CURRENT CONSUMPTION NORMALLY-OFF FAINT SIGNAL DETECTION IC
Rev.1.3_01
S-5470 Series
3. Temperature characteristics of detection current
The shaded area in Figure 17 shows the temperature characteristics of the detection voltage in the operation
temperature range.
IDET [nA]
+0.5%/°C
IDET25*1
−0.5%/°C
−40
+25
+85
Ta [°C]
*1. IDET25: Detection current value at Ta = +25°C
Figure 17 Temperature Characteristics of Detection Current
11