4. Explanation of terms
4. 1 Detection current (IDET)
The detection current (IDET) is the current at which the output switches to "H".
The detection current varies slightly even among products with the same specification. The variation in detection
current from the minimum detection current (IDET min.) to the maximum detection current (IDET max.) is called the
detection current range (refer to Figure 18).
Detection current
IDET max.
IDET min.
Detection
current range
IINP
H
VOUT
L
Figure 18 Detection Current
4. 2 Release current (IREL)
The release current (IREL) is the current at which the output switches to "L".
The release current varies slightly even among products with the same specification. The variation in release
current from the minimum release current (IREL min.) to the maximum release current (IREL max.) is called the
release current range (refer to Figure 19).
The range is calculated from the actual detection current (IDET) of a product and is in the range of IDET × 0.7 ≤
IREL ≤ IDET × 0.9.
IINP
IREL max.
IREL min.
Release current
Release
current range
H
VOUT
L
Figure 19 Release Current
4. 3 Hysteresis width
The hysteresis width is the current difference between the detection current and the release current (current at
point B − current at point A in "Figure 14 Operation when Detecting Certain Current Level" and "Figure 16
Operation when Detecting the Difference of Current Level").
The hysteresis width between the detection current and the release current prevents malfunction caused by
noise in the input current.