English
Language : 

S-8230AAD-I6T1U Datasheet, PDF (5/37 Pages) Seiko Instruments Inc – BATTERY PROTECTION IC
Rev.2.5_00
BATTERY PROTECTION IC WITH DISCHARGE CONTROL FUNCTION FOR 1-CELL PACK
S-8230A/B Series
Table 4
Delay Time
Combination
Overcharge
Detection
Delay Time
[tCU]
Overdischarge
Detection
Delay Time
[tDL]
Discharge
Overcurrent
Detection
Delay Time
[tDIOV]
Load
Short-circuiting
Detection
Delay Time
[tSHORT]
Charge
Overcurrent
Detection
Delay Time
[tCIOV]
Discharge
Inhibition
Delay Time
[tCTL]
(1)
1.0 s
128 ms
16 ms
280 μs
8 ms
256 ms
(2)
1.0 s
128 ms
16 ms
1 ms
8 ms
256 ms
(3)
1.0 s
32 ms
8 ms
280 μs
8 ms
256 ms
(4)
1.0 s
128 ms
32 ms
1 ms
8 ms
256 ms
(5)
1.0 s
64 ms
8 ms
280 μs
8 ms
256 ms
Remark The delay times can be changed within the range listed in Table 5. For details, please contact our sales office.
Table 5
Delay Time
Symbol
Overcharge detection delay time
tCU
Overdischarge detection delay time
tDL
Discharge overcurrent detection delay time tDIOV
Load short-circuiting detection delay time
tSHORT
Charge overcurrent detection delay time
tCIOV
Discharge inhibition delay time
tCTL
*1. This value is the delay time of the standard products.
Selection Range
256 ms 512 ms 1.0 s*1
32 ms 64 ms*1 128 ms
4 ms
8 ms*1
16 ms
280 μs*1 530 μs
1 ms
4 ms
8 ms*1
16 ms
64 ms 128 ms 256 ms*1
Remark
Select a value from the left.
Select a value from the left.
Select a value from the left.
Select a value from the left.
Select a value from the left.
Select a value from the left.
Table 6
Function
Combination
Control
Logic*1
CTL Pin
Internal
Resistance
Connection*2
Internal
Resistance Value*3
[RCTL]
Discharge Inhibition
Status Latch Function *4
0 V Battery
Charge
Function*5
Power-
down
Function*6
Release
Condition
of Discharge
Overcurrent
Status*7
(1)
Active "L" Pull-down
1.0 MΩ
Available
Available
Available
Load
disconnection
(2)
Active "L" Pull-up
1.0 MΩ
Available
Unavailable Available
Charger
connection
(3)
Active "L" Pull-up
5.0 MΩ
Unavailable
Available
Available
Load
disconnection
(4)
Active "L" Pull-down
1.0 MΩ
Available
Unavailable Available
Charger
connection
(5)
Active "L" Pull-up
5.0 MΩ
Unavailable
Available
Unavailable
Load
disconnection
(6)
Active "H" Pull-down
5.0 MΩ
Unavailable
Unavailable Available
Load
disconnection
Caution The combination of CTL pin control logic active "H" and CTL pin internal resistance connection "pull-up"
worsens the accuracy of overcharge detection voltage. Therefore, this combination can not be set up.
*1. CTL pin control logic active "H" / active "L" is selectable.
*2. CTL pin internal resistance connection "pull-up" / "pull-down" is selectable.
*3. CTL pin internal resistance value 1.0 MΩ / 2.5 MΩ / 5.0 MΩ is selectable.
*4. Discharge inhibition status latch function "available" / "unavailable" is selectable.
*5. 0 V battery charge function "available" / "unavailable" is selectable.
*6. Power-down function "available" / "unavailable" is selectable.
*7. Release condition of discharge overcurrent status "load disconnection" / "charger connection" is selectable.
Remark Please contact our sales office for the products with function combinations other than those specified above.
5