English
Language : 

S-8230AAD-I6T1U Datasheet, PDF (4/37 Pages) Seiko Instruments Inc – BATTERY PROTECTION IC
BATTERY PROTECTION IC WITH DISCHARGE CONTROL FUNCTION FOR 1-CELL PACK
S-8230A/B Series
Rev.2.5_00
3. Product name list
3. 1 SNT-6A
3. 1. 1 S-8230A Series
Table 2
Product Name
Overcharge
Detection
Voltage
[VCU]
Overcharge
Release
Voltage
[VCL]
Over-
discharge
Detection
Voltage
[VDL]
Over-
discharge
Release
Voltage
[VDU]
Discharge
Overcurrent
Detection
Voltage
[VDIOV]
S-8230AAD-I6T1U 4.425 V
4.225 V 2.500 V 2.500 V
0.130 V
S-8230AAE-I6T1U 4.415 V
4.215 V 2.500 V 2.900 V
0.050 V
S-8230AAF-I6T1U 4.425 V
4.225 V 2.800 V 2.800 V
0.130 V
*1. Refer to Table 4 about the details of the delay time combinations.
*2. Refer to Table 6 about the details of the function combinations.
Charge
Overcurrent
Detection
Voltage
[VCIOV]
−0.100 V
−0.040 V
−0.100 V
Delay Time Function
Combination*1 Combination*2
(3)
(3)
(5)
(5)
(3)
(6)
Remark Please contact our sales office for the products with detection voltage value other than those specified above.
3. 1. 2 S-8230B Series
Table 3
Product Name
Overcharge
Detection
Voltage
[VCU]
Overcharge
Release
Voltage
[VCL]
Over-
discharge
Detection
Voltage
[VDL]
Over-
discharge
Release
Voltage
[VDU]
Discharge
Overcurrent
Detection
Voltage
[VDIOV]
S-8230BAA-I6T1U 4.280 V
4.080 V 2.300 V 2.300 V
0.080 V
S-8230BAB-I6T1U 4.280 V
3.880 V 2.500 V 3.000 V
0.200 V
S-8230BAE-I6T1U 4.280 V
3.880 V 2.300 V 2.300 V
0.140 V
S-8230BAF-I6T1U 4.425 V
4.225 V 2.500 V 2.500 V
0.130 V
S-8230BAG-I6T1U 4.425 V
4.225 V 2.500 V 2.500 V
0.130 V
*1. Refer to Table 4 about the details of the delay time combinations.
*2. Refer to Table 6 about the details of the function combinations.
Charge
Overcurrent
Detection
Voltage
[VCIOV]
−0.100 V
−0.050 V
−0.050 V
−0.100 V
−0.050 V
Delay Time Function
Combination*1 Combination*2
(1)
(1)
(2)
(2)
(4)
(4)
(3)
(1)
(2)
(2)
Remark Please contact our sales office for the products with detection voltage value other than those specified above.
4