 Absolute Maximum Ratings
Table 3
Item
Symbol
Absolute Maximum Rating
Unit
Power supply voltage
VCC
−0.3 to +7.0
V
Input voltage
VIN
−0.3 to +7.0
V
Output voltage
VOUT
−0.3 to VCC + 0.3
V
Operating ambient temperature
Topr
−40 to +105
°C
Storage temperature
Tstg
−65 to +150
°C
Caution The absolute maximum ratings are rated values exceeding which the product could suffer
physical damage. These values must therefore not be exceeded under any conditions.
 Recommended Operating Conditions
Item
Power supply voltage
High level input voltage
Low level input voltage
Table 4
Symbol
Condition
VCC
Read operation
Write operation
VIH
VCC = 2.5 V to 5.5 V
VIL
VCC = 2.5 V to 5.5 V
Ta = −40°C to +105°C
Min.
Max.
Unit
2.5
5.5
V
2.5
5.5
V
0.7 × VCC
VCC + 1.0
V
−0.3
0.3 × VCC
V
 Pin Capacitance
Item
Input capacitance
Output capacitance
Symbol
Table 5
Condition
(Ta = +25°C, f = 1.0 MHz, VCC = 5 V)
Min.
Max.
Unit
CIN
VIN = 0 V ( CS , SCK, SI, WP , HOLD )
−
COUT VOUT = 0 V (SO)
−
8
pF
10
pF
 Endurance
Table 6
Item
Symbol Operating Ambient Temperature
Endurance
NW
−40°C to +85°C
−40°C to +105°C
*1. For each address (Word: 8 bits)
Min.
106
8 × 105
 Data Retention
Item
Data retention
Table 7
Symbol Operation Ambient Temperature
Min.
−
+25°C
100
−40°C to +105°C
50
Max.
−
−
Unit
cycles / word*1
cycles / word*1
Max.
Unit
−
year
−
year