English
Language : 

S-25C010A-H Datasheet, PDF (21/33 Pages) Seiko Instruments Inc – OPERATION SPI SERIAL E2PROM FOR AUTOMOTIVE
Rev.2.3_01_C
105°C OPERATION SPI SERIAL E2PROM FOR AUTOMOTIVE
S-25C010A/020A/040A H Series
CS
WP
SCK
SI
High
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
Instruction
X
8-bit Address
Data Byte (n)
Data Byte (n+x)
A7*1 A6 A5 A4 A3 A2 A1 A0 D7 D6 D5 D4 D3 D2 D1 D0 D4 D3 D2 D1 D0
High-Z
SO
*1 In the S-25C010A, A7 = Don’t care because the address range is A6 to A0.
Remark X = Don’t care.
Figure 19 WRITE Operation (Page) (S-25C010A/020A)
CS
WP
SCK
SI
High
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
Instruction
A8*1
8-bit Address
Data Byte (n)
Data Byte (n + x)
A7 A6 A5 A4 A3 A2 A1 A0 D7 D6 D5 D4 D3 D2 D1 D0 D4 D3 D2 D1 D0
High-Z
SO
*1 In the S-25C040A, assign bit A8 in the address into the fifth bit in an instruction code.
Figure 20 WRITE Operation (Page) (S-25C040A)
21