English
Language : 

S-19680AAAH-K8T2U Datasheet, PDF (4/27 Pages) Seiko Instruments Inc – Current consumption during operation
FOR AUTOMOTIVE 105°C OPERATION CURRENT MONITOR HIGH SIDE SWITCH
S-19680 Series
Rev.1.1_00
4. Product name list
4. 1 S-19680 Series A type
Table 3
Product Name
S-19680AAAH-K8T2U
Limit Current (ILIM)
40 mA
Load Short-circuit Detection
Current (ISHORT)
40 mA
Load Open Detection Current
(IOPEN)
2.5 mA
S-19680AABH-K8T2U
100 mA
50 mA
10 mA
Remark Please contact our sales office for products with specifications other than the above.
4. 2 S-19680 Series B type
Table 4
Product Name
Limit Current (ILIM)
Load Short-circuit Detection
Current (ISHORT)
Load Open Detection Current
(IOPEN)
S-19680BAAH-K8T2U
50 mA
40 mA
5.0 mA
S-19680BABH-K8T2U
50 mA
35 mA
7.5 mA
S-19680BACH-K8T2U
100 mA
50 mA
10 mA
S-19680BADH-K8T2U
100 mA
50 mA
5.0 mA
S-19680BAEH-K8T2U
60 mA
54 mA
15 mA
S-19680BAFH-K8T2U
70 mA
70 mA
5.0 mA
Remark Please contact our sales office for products with specifications other than the above.
4