English
Language : 

S-19680AAAH-K8T2U Datasheet, PDF (20/27 Pages) Seiko Instruments Inc – Current consumption during operation
FOR AUTOMOTIVE 105°C OPERATION CURRENT MONITOR HIGH SIDE SWITCH
S-19680 Series
Rev.1.1_00
11. Power supply fluctuation characteristics (ILIM = 100 mA, ISHORT = 40 mA, IOPEN = 2.5 mA product)
11. 1 Load normal status (IOPEN ˂ IOUT ˂ ISHORT)
11. 2 Load open status (IOUT ˂ IOPEN)
VDD = 2.7 V ↔ 10.0 V (0.1 V/μs),
CL = 0.1 μF, IOUT = 20 mA, Ta = +25°C
VDD = 2.7 V ↔ 10.0 V (0.1 V/μs),
CL = 0.1 μF, IOUT = 0.01 mA, Ta= +25°C
VDD
5 V / div.
GND
VOUT
5 V / div.
GND
IOUT
50 mA / div.
GND
VSC
"H"
"L"
VOL
"H"
"L"
0.0 0.5 1.0 1.5 2.0 2.5 3.0
Time [ms]
VDD
5 V / div.
GND
VOUT
5 V / div.
GND
50 mA / div.
IOUT
GND
VSC
"H"
"L"
VOL
"H"
"L"
0.0 0.5 1.0 1.5 2.0 2.5 3.0
Time [ms]
11. 3 Load short-circuit status (ISHORT ˂ IOUT ˂ ILIM)
VDD = 2.7 V ↔ 10.0 V (0.1 V/μs),
CL = 0.1 μF, IOUT = 60 mA, Ta = +25°C
VDD
5 V / div.
GND
VOUT
5 V / div.
GND
IOUT
50 mA / div.
GND
VSC
"H"
"L"
VOL
"H"
"L"
0.0 0.5 1.0 1.5 2.0 2.5 3.0
Time [ms]
20