S-80819CNMC-B8ET2G Datasheet, PDF (28/56 Pages) Seiko Instruments Inc – SUPER-SMALL PACKAGE HIGH-PRECISION VOLTAGE DETECTOR | |||
|
◁ |
SUPER-SMALL PACKAGE HIGH-PRECISION VOLTAGE DETECTOR
S-808xxC Series
Rev.6.1_00
2. S-80844KLUA-D2AT2x, S-80844KLY-n2-U
Table 19
(Ta = 25 °C unless otherwise specified)
Item
Detection voltage*1
Release voltage
Current consumption
Operating voltage
Output current
Response time
Detection voltage
temperature
coefficient*3
Symbol
Condition
Min.
âVDET
+VDET
ISS
VDD
IOUT
tPLH
â¯
â¯
VDD = 6.0 V
â¯
Output transistor, VDD = 1.2 V
Nch, VDS = 0.5 V VDD = 2.4 V
Output transistor,
Pch, VDS = 0.5 V
VDD = 4.8 V
â¯
4.295
â¯
â¯
0.95
0.23
1.60
0.36
â¯
Î â VDET
Ta = â40 to 85 °C
â¯
ÎTa ⢠âVDET
Typ.
4.450*2
â¯
1.0
â¯
0.50
3.70
0.62
â¯
±100
Max.
4.605
4.700
3.0
10.0
â¯
â¯
â¯
60
Unit
Test
circuit
V
1
V
1
μA
2
V
1
mA
3
mA
3
mA
4
μs
1
±350 ppm/°C 1
*1. âVDET: Actual detection voltage value
*2. Specified detection voltage value (âVDET(S))
*3. The temperature change of the detection voltage [mV/°C] is calculated by using the following equation.
[ ] [ ] [ ] ( ) Î â VDET mV/°C *1 = âVDET(S) Typ. V *2 à Πâ VDET ppm/°C *3 ÷ 1000
ÎTa
ÎTa ⢠âVDET
*1. Temperature change of the detection voltage
*2. Specified detection voltage
*3. Detection voltage temperature coefficient
28