S-80819CNMC-B8ET2G Datasheet, PDF (27/56 Pages) Seiko Instruments Inc – SUPER-SMALL PACKAGE HIGH-PRECISION VOLTAGE DETECTOR | |||
|
◁ |
Rev.6.1_00
SUPER-SMALL PACKAGE HIGH-PRECISION VOLTAGE DETECTOR
S-808xxC Series
 Electrical Characteristics for Customized Products
1. S-80824KNUA-D2BT2x, S-80824KNY-n2-U
Table 18
(Ta = 25 °C unless otherwise specified)
Item
Symbol
Condition
Min.
Detection voltage*1
Release voltage
Current consumption
Operating voltage
Output current
Leakage current
Response time
Detection voltage
temperature
coefficient*3
âVDET
+VDET
ISS
VDD
IOUT
ILEAK
tPLH
â¯
â¯
VDD=6.0 V
â¯
Output transistor, VDD = 0.95 V
Nch, VDS = 0.5 V VDD = 1.2 V
Output transistor,
Nch, VDD = 10.0 V, VDS = 10.0 V
â¯
Î â VDET
ÎTa ⢠âVDET
Ta = â40 to 85 °C
2.295
4.300
â¯
0.95
0.03
0.23
â¯
â¯
â¯
Typ.
2.400*2
4.400
0.8
â¯
0.24
0.50
â¯
â¯
±100
Max.
2.505
4.500
2.4
10.0
â¯
â¯
0.1
60
±350
Unit
Test
circuit
V
1
V
1
μA
2
V
1
mA
3
mA
3
μA
3
μs
1
ppm/°C 1
*1. âVDET: Actual detection voltage value
*2. Specified detection voltage value (âVDET(S))
*3. The temperature change of the detection voltage [mV/°C] is calculated by using the following equation.
[ ] [ ] [ ] ( ) Î â VDET mV/°C *1 = âVDET(S) Typ. V *2 à Πâ VDET ppm/°C *3 ÷ 1000
ÎTa
ÎTa ⢠âVDET
*1. Temperature change of the detection voltage
*2. Specified detection voltage
*3. Detection voltage temperature coefficient
Seiko Instruments Inc.
27
|
▷ |