English
Language : 

S-19103N10H-M5T1U Datasheet, PDF (20/34 Pages) Seiko Instruments Inc – VOLTAGE DETECTOR WITH SENSE PIN
FOR AUTOMOTIVE 105°C OPERATION VOLTAGE DETECTOR WITH SENSE PIN
S-19103/19109 Series
Rev.1.2_01
2. 5 Malfunction when VDD falls
As seen in Figure 26, note that if the VDD pin voltage (VDD) drops steeply below 1.2 V when −VDET < VSENSE <
−VDET × 1.05, erroneous detection may occur.
When VDD_Low ≥ 1.2 V, erroneous detection does not occur.
When VDD_Low < 1.2 V, the more the VDD falling amplitude increases or the shorter the falling time becomes, the
easier the erroneous detection.
Perform thorough evaluation in actual application.
VDD
VDD_High
VDD_Low (Voltage drops below 1.2 V.)
VSENSE
−VDET × 1.05
−VDET
VOUT
VOUT falling influenced by VDD falling
(erroneous detection)
Figure 26
The S-19103C50 example in Figure 27 shows an example of erroneous detection boundary conditions.
Remark
12
10
8
Danger of erroneous
6
detection
4
2
0
0.1
1
10
100 1000
tF [s]
Figure 27
Test conditions
Product name: S-19103C50
VSENSE:
VDD_High:
VDD_Low:
ΔVDD:
tF:
−VDET(S) + 0.1 V
VDD pin voltage before falling
VDD pin voltage after falling (0.95 V)
VDD_High − VDD_Low
Falling time of VDD from VDD_High − ΔVDD × 10% to VDD_Low + ΔVDD × 10%
VDD_High
VDD_High  VDD  10%
VDD
VDD_Low  VDD  10%
VDD_Low
tF
Figure 28