 Battery Protection IC Connection Example
(1) Connection Example 1
SC PROTECTOR
RVCC
EB+
R1
BAT1
C1
SENSE
VCC
CVCC
VC1
R2
BAT2
C2
VC2
R3
BAT3
C3
ICT
CICT
VC3
R4
BAT4
C4
FET
VSS
CO
EB−
Figure 8
Table 9 Constants for External Components 1
Symbol
Min.
Typ.
Max.
Unit
R1 to R4
0
1k
10 k
Ω
C1 to C4
0
0.1
1
μF
RVCC
0
CVCC
0
CICT
0
100
1k
Ω
0.1
1
μF
0.1
1
μF
Caution1. The above constants may be changed without notice.
2. It has not been confirmed whether the operation is normal or not in circuits other than the above
example of connection. In addition, the example of connection shown above and the constant do
not guarantee proper operation. Perform thorough evaluation using the actual application to set
the constant.