S-8244AAAPH-CEATFU Datasheet, PDF (11/32 Pages) Seiko Instruments Inc – BATTERY PROTECTION IC FOR 1-SERIAL TO 4-SERIAL-CELL PACK | |||
|
◁ |
BATTERY PROTECTION IC FOR 1-SERIAL TO 4-SERIAL-CELL PACK (SECONDARY PROTECTION)
Rev.6.4_02
S-8244 Series
(4) Test Condition 4, Test Circuit 1
Set switches 1 and 2 to OFF for CMOS output product.
Set switch 1 to ON and switch 2 to OFF for Nch open drain product.
Set switch 1 to OFF and switch 2 to ON for Pch open drain product.
⢠Product with CMOS output active âHâ, Nch open drain output active âHâ
The overcharge detection voltage 4 (VCU4) is a voltage at V4; when the CO pinâs voltage is set to âHâ by increasing
V4 gradually, after setting V1 = V2 = V3 = V4 = 3.5 V. After that, gradually decreasing V4âs voltage to set CO = âLâ,
and the difference of this V4âs voltage and VCU4 is the overcharge hysteresis voltage 4 (VCD4).
⢠Product with CMOS output active âLâ, Nch open drain output active âLâ, Pch open drain output active âLâ
The overcharge detection voltage 4 (VCU4) is a voltage at V4; when the CO pinâs voltage is set to âLâ by increasing
V4 gradually, after setting V1 = V2 = V3 = V4 = 3.5 V. After that, gradually decreasing V4âs voltage to set CO =
âHâ, and the difference of this V4âs voltage and VCU4 is the overcharge hysteresis voltage 4 (VCD4).
(5) Test Condition 5, Test Circuit 2
Set switches 1 and 2 to OFF for CMOS output product.
Set switch 1 to ON and switch 2 to OFF for Nch open drain product.
Set switch 1 to OFF and switch 2 to ON for Pch open drain product.
⢠Product with CMOS output active âHâ, Nch open drain output active âHâ
Rise V1 to 4.7 V momentarily within 10 μs after setting V1 = V2 = V3 = V4 = 3.5 V. The period from V1 having
reached 4.7 V to CO = âHâ is the overcharge detection delay time (tCU).
⢠Product with CMOS output active âLâ, Nch open drain output active âLâ, Pch open drain output active âLâ
Rise V1 to 4.7 V momentarily within 10 μs after setting V1 = V2 = V3 = V4 = 3.5 V. The period from V1 having
reached 4.7 V to CO = âLâ is the overcharge detection delay time (tCU).
(6) Test Condition 6, Test Circuit 3
Measure current consumption (I1) setting V1 = V2 = V3 = V4 = 2.3 V. This I1 is current consumption at power-down
(IPDN).
Measure current consumption (I1) setting V1 = V2 = V3 = V4 = 3.5 V. This I1 is current consumption during normal
operation (IOPE), I2 is the VC1 sink current (IVC1), I3 is the VC2 sink current (IVC2), I4 is the VC3 sink current (IVC3).
11
|
▷ |