Rev.2.3_00
ULTRA-SMALL PACKAGE HIGH-PRECISION VOLTAGE DETECTOR
S-1000 Series
2. 3 Temperature characteristics of hysteresis voltage
The temperature changes of the hysteresis voltage is expressed as â + VDET â â â VDET and is calculated as
âTa
âTa
follows:
â + VDET â â â VDET = VHYS Ã â â VDET
âTa
âTa â VDET âTa
 Standard Circuit
VDD
OUT
VSS
R*1
100 kâ¦
*1. R is unnecessary for CMOS output products.
Figure 17
Caution The above connection diagram and constants do not guarantee correct operation. Perform sufficient
evaluation using the actual application to set the constants.
 Explanation of Terms
1. Detection voltage (âVDET), release voltage (+VDET)
The detection voltage (âVDET) is a voltage at which the output turns to âLâ. The detection voltage varies slightly among
products of the same specification. The variation of detection voltage between the specified minimum (âVDET) Min. and the
maximum (âVDET) Max. is called the detection voltage range (Refer to Figure 18).
Example: For the S-1000C15, the detection voltage lies in the range of 1.485 ⤠(âVDET) ⤠1.515.
This means that some S-1000C15s have 1.485 V for âVDET and some have 1.515 V.
The release voltage is a voltage at which the output turns to âHâ. The release voltage varies slightly among products of
the same specification. The variation of release voltages between the specified minimum (+VDET) Min. and the maximum
(+VDET) Max. is called the release voltage range (Refer to Figure 19). The range is calculed from the actual detection
voltage (âVDET) of a product and is expressed by âVDET à 1.03 ⤠+VDET ⤠âVDET à 1.07.
Example: For the S-1000C15, the release voltage lies in the range of 1.530 ⤠(+VDET) ⤠1.621.
This means that some S-1000C15s have 1.530 V for +VDET and some have 1.621 V.