English
Language : 

S-1000 Datasheet, PDF (15/38 Pages) Seiko Instruments Inc – ULTRA-SMALL PACKAGE HIGH-PRECISION VOLTAGE DETECTOR
Rev.2.3_00
ULTRA-SMALL PACKAGE HIGH-PRECISION VOLTAGE DETECTOR
S-1000 Series
2. 3 Temperature characteristics of hysteresis voltage
The temperature changes of the hysteresis voltage is expressed as ∆ + VDET − ∆ − VDET and is calculated as
∆Ta
∆Ta
follows:
∆ + VDET − ∆ − VDET = VHYS × ∆ − VDET
∆Ta
∆Ta − VDET ∆Ta
„ Standard Circuit
VDD
OUT
VSS
R*1
100 kΩ
*1. R is unnecessary for CMOS output products.
Figure 17
Caution The above connection diagram and constants do not guarantee correct operation. Perform sufficient
evaluation using the actual application to set the constants.
„ Explanation of Terms
1. Detection voltage (−VDET), release voltage (+VDET)
The detection voltage (−VDET) is a voltage at which the output turns to “L”. The detection voltage varies slightly among
products of the same specification. The variation of detection voltage between the specified minimum (−VDET) Min. and the
maximum (−VDET) Max. is called the detection voltage range (Refer to Figure 18).
Example: For the S-1000C15, the detection voltage lies in the range of 1.485 ≤ (−VDET) ≤ 1.515.
This means that some S-1000C15s have 1.485 V for −VDET and some have 1.515 V.
The release voltage is a voltage at which the output turns to “H”. The release voltage varies slightly among products of
the same specification. The variation of release voltages between the specified minimum (+VDET) Min. and the maximum
(+VDET) Max. is called the release voltage range (Refer to Figure 19). The range is calculed from the actual detection
voltage (−VDET) of a product and is expressed by −VDET × 1.03 ≤ +VDET ≤ −VDET × 1.07.
Example: For the S-1000C15, the release voltage lies in the range of 1.530 ≤ (+VDET) ≤ 1.621.
This means that some S-1000C15s have 1.530 V for +VDET and some have 1.621 V.
Seiko Instruments Inc.
15