English
Language : 

S-57B1 Datasheet, PDF (11/20 Pages) Seiko Instruments Inc – OPERATION HIGH-SPEED UNIPOLAR DETECTION TYPE HALL IC
125°C OPERATION HIGH-SPEED UNIPOLAR DETECTION TYPE HALL IC
Rev.3.0_00
S-57B1 Series
3. Basic operation
This IC changes the output voltage level (VOUT) according to the level of the magnetic flux density (S pole) applied by
a magnet.
The following explains the operation when the magnetism detection logic is active "L".
When the magnetic flux density vertical to the marking surface exceeds the operation point (BOPS) after the south pole
of a magnet is moved closer to the marking surface of this IC, VOUT changes from "H" to "L". When the south pole of a
magnet is moved further away from the marking surface of this IC and the magnetic flux density is lower than the
release point (BRPS), VOUT changes from "L" to "H".
Figure 12 shows the relationship between the magnetic flux density and VOUT.
VOUT
BHYSS
H
N pole
0
BRPS
Magnetic flux density (B)
BOPS
Figure 12
L
S pole
11