TLE 5216 G
(CS = L), all error reports can be shifted out serially. The rising edge of the CS will reset
all error registers. The function of the serial diagnostic interface is shown in figure 7.
The data input (SERIN) allows several TLE 5216 G or other serial diagnostic interfaces
to be cascaded.
A LOW signal on the reset pin (RESET) or a supply voltage lower than the operating
range (4.5 V) will erase the error register and disable all four power switches.
Absolute Maximum Ratings
Tj = – 40 °C to 150 °C
Parameter
Symbol
Supply voltage
VS
Input voltages IN1 … IN4, SERIN, CLK, CS, RESET VIN
Status output voltage Data OUT (SEROUT)
VSEROUT
Operating temperature range
Tj
Storage temperature range
TStg
Output current per channel
Tj = 25 °C ID(AZ)
Tj = 125 °C ID(AZ)
Ground pin current
Tj = 25 °C IGND
Tj = 125 °C IGND
Thermal resistance (junction-case static)
See diagrams P-DSO-20-10 RthJC
Transient thermal impendance
tp = 100 µs; square pulse ZthJC
tp = 100 µs; triangle pulse ZthJC
Values Unit
– 2 … 40
V
– 0.3 … 7
V
– 0.3 … 10 V
– 40 … 150 °C
– 50 … 150 °C
– 3.8 … 3.8 A
– 2.95 … 2.95 A
– 10 … 10 A
–8…8
A
5
K/W
0.5
K/W
0.2
K/W
Note: Maximum ratings are absolute ratings; exceeding only one of these values may
cause irreversible damage to the integrated circuit.
Semiconductor Group
6
1998-06-22