English
Language : 

SDA9270 Datasheet, PDF (27/33 Pages) Siemens Semiconductor Group – ICs for Consumer Electronics
SDA 9270
3.2 Recommended Operating Conditions (cont’d)
Parameter
Symbol
Limit Values
min. typ. max.
Hold time DATA
tHD;DAT
0
SDA/SCL rise times
tR
300
SDA/SCL fall times
tF
300
Set-up time stop condition
tSU;STO
0.6
Low-level output current
IOL
3
Unit
µs
ns
ns
µs
mA
Test
Conditions
fSCL = 400 kHz
Note: Under this conditions the functions given in the circuit description are fulfilled.
Nominal conditions specify mean values expected over the production spread and
are the proposed values for interface and application. If not stated otherwise,
nominal values will apply at TA = 25 ˚C and the nominal supply voltage.
Semiconductor Group
27