English
Language : 

HYB39S16400-1 Datasheet, PDF (17/19 Pages) Siemens Semiconductor Group – 16 MBit Synchronous DRAM
HYB 39S16400/800/160CT-8/-10
16 MBit Synchronous DRAM
Notes for AC Parameters
1. For proper power-up see the operation section of this data sheet.
2. AC timing tests for LV-TTL versions have VIL = 0.4 V and VIH = 2.4 V with the timing referenced
to the 1.5 V crossover point. The transition time is measured between VIH and VIL. All AC
measurements assume tT = 1 ns with the AC output load circuit shown in figure below. Specified
tAC and tOH parameters are measured with a 50 pF only, without any resistive termination and
with a input signal of 1V/ s edge rate between 0.8 V and 2.0 V.
CLOCK
t CL
t SETUP
t HOLD
INPUT
OUTPUT
1.4 V
tAC
t LZ
t CH
2.4 V
0.4 V
tT
tAC
t OH
1.4 V
t HZ
SPT03404
I/O
50 pF
Measurement conditions for
tAC and tOH
3. If clock rising time is longer than 1 ns, a time (tT/2 - 0.5) ns has to be added to this parameter.
4. If tT is longer than 1 ns, a time (tT -1) ns has to be added to this parameter.
5. These parameter account for the number of clock cycle and depend on the operating frequency
of the clock, as follows:
the number of clock cycle = specified value of timing period (counted in fractions as a whole
number)
Self Refresh Exit is a synchronous operation and begins on the 2nd positive clock edge after
CKE returns high. Self Refresh Exit is not complete until a time period equal to tRC is satisfied
once the Self Refresh Exit command is registered.
Semiconductor Group
17
1998-10-01