LQ043T1DG02 Datasheet, PDF (18/25 Pages) Sharp Electrionic Components – AVC Liquid Crystal Displays Group | |||
|
◁ |
LCY-W-06901 Page 15 of 21
ã Note 5 ãDefinition of Uniformity.
Uniformity = Minimum Brightness Ã100 (%)
Maximum Brightness
The brightness should be measured on the 9-point as shown in the following figure.
1/6
1/6
10. Mechanical characteristics
10-1) FPC (for LCD panel) characteristics
(1) Specific connector: FH12A-40S-0.5SH(55) (HIROSE)
(2) Bending endurance of the bending slits portion
No line of the FPC is broken for the bending test (Bending radius=0.6mm and
angle=90°) in 30 cycles.
11. Handling of modules
11-1 Inserting the FPC into its connector and pulling it out.
â Be sure to turn off the power supply and the signals when inserting or disconnecting the cable.
â¡ Please insert for too much stress not to join FPC in the case of insertion of FPC.
11-2 About handling of FPC
â The bending radius of the FPC should be more than 1.4mm, and it should be bent evenly.
â¡ Do not dangle the LCD module by holding the FPC, or do not give any stress to it.
11-3 Mounting of the module
â The module should be held on to the plain surface. Do not give any warping or twisting stress to
the module.
â¡ Please consider that GND can ground a modular metal portion etc. so that static electricity is not
charged to a module.
|
▷ |