LCY-W-06901 Page 15 of 21
【 Note 5 】Definition of Uniformity.
Uniformity = Minimum Brightness ×100 (%)
Maximum Brightness
The brightness should be measured on the 9-point as shown in the following figure.
1/6
1/6
10. Mechanical characteristics
10-1) FPC (for LCD panel) characteristics
(1) Specific connector: FH12A-40S-0.5SH(55) (HIROSE)
(2) Bending endurance of the bending slits portion
No line of the FPC is broken for the bending test (Bending radius=0.6mm and
angle=90°) in 30 cycles.
11. Handling of modules
11-1 Inserting the FPC into its connector and pulling it out.
① Be sure to turn off the power supply and the signals when inserting or disconnecting the cable.
② Please insert for too much stress not to join FPC in the case of insertion of FPC.
11-2 About handling of FPC
① The bending radius of the FPC should be more than 1.4mm, and it should be bent evenly.
② Do not dangle the LCD module by holding the FPC, or do not give any stress to it.
11-3 Mounting of the module
① The module should be held on to the plain surface. Do not give any warping or twisting stress to
the module.
② Please consider that GND can ground a modular metal portion etc. so that static electricity is not
charged to a module.