English
Language : 

50162801 Datasheet, PDF (2/8 Pages) Sensortechnics GmbH – High energy physics
Near Ultraviolet (NUV) SiPMs
Absolute maximum ratings (1)
Parameter
Min.
Operating temperature (T )
-25
A
Storage temperature (T )
-40
S
Lead temperature (solder) 5 s (T )
Sol
Voltage working range (MVW)
Max.
Unit
+40
°C
+60
°C
+250
°C
Breakdown voltage +6
V
Typical characteristics
Parameter
Effective active area
Cell count
Cell size (pitch)
Cell fill-factor
Quenching resistance
Cell capacitance
Recharge time constant
Spectral response range
Peak sensitivity wavelength
Photon detection efficiency (2)
Breakdown voltage (BV)
BV standard deviation (3)
Recommended overvoltage range (OV) (4)
Dark count rate (5)
Gain (6)
Breakdown voltage temperature coefficient
Refractive index of epoxy resin (7)
Spectral transmission of epoxy resin (7)
Product
SiPM-NUV1S-SMD
SiPM-NUV1C-SMD
(1×1) mm2
1.13 mm2
625
673
40 μm × 40 μm
60 %
800 kΩ
90 fF
70 ns
350 ... 900 nm
420 nm
43 %
typ. 26 V, min. 24 V, max. 28 V
50 mV
min: 2 V, max: 6 V
<50 kHz/mm2 @ 2 V OV, <100 kHz/mm2 @ 6 V OV
3.6×106
26 mV/°C
1.5115 (@ 589 nm, 23 °C, uncured)
>97% @ 1000 ... 1600 nm ; >99% @ 400 ... 1000 nm
SiPM-NUV3S-SMD
(3×3) mm2
5520
SiPM-NUV4S-SMD
(4×4) mm2
9340
Specification notes
(1) Stresses beyond those listed under “Absolute Maximum Ratings” may cause
permanent damage to the device. These are stress ratings only, and functional
operation of the device at these or any other conditions beyond those indicated
in the operational sections of the specifications is not implied. Exposure to
absolute maximum rated conditions for extended periods may affect device
reliability.
(2) Measured at peak sensitivity wavelength (λ=λp) at +6 V overvoltage (not
including afterpulse and crosstalk).
(3) BV of SiPMs belonging to a same production lot are within 200 mV (±2σ) from
mean BV value.
(4) Operating voltage (SiPM bias) is BV+OV, to be applied in reverse mode, i.e.
V <0 (see “Pins Function” section).
AK
(5) 0.5 p.e. threshold level at 20 °C (primary dark count rate; not including afterpulse).
(6) Measured at 20 °C at +6 V overvoltage.
(7) To be used as a guide only, not as a specification. Reported data is not guaranteed.
Version 29-07-15
Subject to change without notice
www.first-sensor.com
contact@first-sensor.com