English
Language : 

LC9998G Datasheet, PDF (7/11 Pages) Sanyo Semicon Device – 1/5 Optical Size PAL Color Solid-State Image Sensor
LC9998G
4. Smear
• Place a 1/10 V chart in front of the halogen light source as shown in the figure and image that chart.
• Adjust the amount of light entering the CCD with ND filters so that the CCD output signal at point A becomes
250 mV.
• Remove the ND filter(s) and measure the output value of the CCD output signal from the first line (point B).
SM = VB · TND × 100 [%]
250
VB: The amount of smear at point B [mV]
TND: The ND filter transmissivity
Figure 5
5. Dark Signal
Completely block all light from falling on the CCD element surface and measure the CCD output signal at the center
of the image.
Here, do not measure the difference between this signal and the optical black section level, but rather measure the
difference between this signal and the no signal level that has no pixel information. (See Figure 6.)
Figure 6 Structure of a Single Horizontal Period
No.5219-7/11