EP610 Datasheet, PDF (8/9 Pages) Rochester Electronics – High-performance, 16-macrocell Classic EPLD Pipelined data rates of up to 100 MHz
EP610
AC Operating Conditions: EP610-XX/B Note (1)
Symbol
tPD1
tPD2
tPZX
tPXZ
tCLR
fMAX
tSU
tH
tCH
tCL
tCO1
tCNT
fCNT
tASU
tAH
tACH
tACL
tACO1
tACNT
fACNT
Parameter
Conditions
Min Max Unit
Input to non-registered output
35
ns
I/O input to non-registered output
C1 = 35 pF Notes (2), (3)
37
ns
Input to output enable
35
ns
Input to output disable
C1 = 5 pF Notes (2), (3), (4), (5)
35
ns
Asynchronous output clear time
C1 = 35 pF Notes (2), (3)
37
ns
Maximum clock frequency
Note (2), (6), (7)
37.0
MHz
Global clock input setup time
Note (2), (3)
27
ns
Global clock input hold time
Note (3)
0
ns
Global clock high time
Note (4)
12
ns
Global clock low time
Note (4)
12
ns
Global clock to output delay
20
ns
Global clock minimum period
Note (4), (8)
35
ns
Global clock internal maximum frequency
Note (8)
28.5
MHz
Array clock input setup time
Notes (2), (3), (4)
8
ns
Array clock input hold time
Notes (2), (3), (4)
12
ns
Array clock high time
Notes (3), (4)
12
ns
Array clock low time
Notes (3), (4)
12
ns
Array clock to output delay
Notes (2), (3)
37
ns
Array clock minimum period
Notes (4), (8)
35
ns
Array clock internal maximum frequency
Notes (4), (8)
28.6
MHz
Notes to tables:
(1) Screening and characterization of AC delay parameters are conducted at 10 MHz or less.
Operating conditions: VCC = 5 V ± 10%, TC = -55° C to 125° C for military use.
(2) All array-dependent delays are specified for an XOR pattern. This pattern includes two product terms and two
pure inputs; all other product terms in the macrocell are held low by one EPROM cell. Other patterns may result
in longer delays. Delays for patterns involving only one product term (such as tPXZ ) are specified for an XOR
pattern in which only one pure input switches at a time.
(3) When the Turbo Bit is not set (non-turbo mode), a non-turbo adder of 30 ns (maximum) is added to this
parameter to determine worst-case timing. Parameters may not be tested in non-turbo mode, but are
guaranteed to the limits specified. Devices operating in non-turbo mode require one input or I/O transition to
guarantee that the device will enter the correct power-up state.
(4) These parameters may not be tested, but are guaranteed to the limits specified in the table under “Absolute
Maximum Ratings” on page 3.
(5) Not tested directly, but guaranteed by testing tPD.
(6) The fMAX values represent the highest frequency for pipelined data.
(7) Not tested directly, but derived from tSU.
(8) Specified with device programmed as a 16-bit counter with no output loading.
Specification Number EP610-CI (AT) REV -