EP610
AC Operating Conditions: EP610-15 & EP610-20 Note (1)
EP610-25 EP610-20
EP610-25T EP610-20T
EP610-35
Non-
Turbo
Adder
Symbol
Parameter
Conditions Min Max Min Max Min Max
Unit
tPD1
Input to non-registered output C1 = 35 pF
25
30
35
tPD2 I/O input to non-registered output
27
32
37
tPZX
Input to output enable
25
30
35
tPXZ
Input to output disable
C1 = 5 pF
Note (2)
25
30
35
tCLR
Asynchronous output clear time C1 = 35 pF
27
32
37
tIO
I/O input pad and buffer delay
2
2
2
fMAX
Maximum clock frequency
Note (3) 47.6
41.7
37.0
tSU
Global clock input setup time
21
24
27
tH
Global clock input hold time
0
0
0
tCH
Global clock high time
10
11
12
tCL
Global clock low time
10
11
12
tCO1
Global clock to output delay
15
17
20
tCNT
Global clock minimum period
25
30
35
fCNT
Global clock internal maximum
frequency
Note (4) 40.0
33.3
28.6
tASU
tAH
tACH
tACL
tACO1
tACNT
fACNT
Array clock input setup time
Array clock input hold time
Array clock high time
Array clock low time
Array clock to output delay
Array clock minimum period
Array clock internal maximum
frequency
Note (4)
8
8
8
12
12
12
10
11
12
10
11
12
27
32
37
25
30
35
40.0
33.3
28.6
30
ns
30
ns
30
ns
30
ns
30
ns
0
ns
0 MHz
30
ns
0
ns
0
ns
0
ns
0
ns
0
ns
0 MHz
30
ns
0
ns
0
ns
0
ns
30
ns
0
ns
0 MHz
Notes to tables:
(1) Operating conditions: VCC = 5 V ± 5%, TA = 0° C to 70° C for commercial use.
VCC = 5 V ± 10%, TA = -40° C to 85° C for industrial use.
VCC = 5 V ± 10%, TC = -55° C to 125° C for military use.
(2) Sample-tested only for an output change of 500 mV.
(3) The fMAX values represent the highest frequency for pipelined data.
(4) Measured with a device programmed as a 16-bit counter. ICC measured at 0° C.
Specification Number EP610-CI (AT) REV -
Page 7 of 9