English
Language : 

RH850F1L Datasheet, PDF (8/16 Pages) Renesas Technology Corp – Emulator
RH850/F1L Series E1/E20 Emulator Release Note(Restrictions when using CubeSuite+)
No. 16 Regarding time measurement function
[Description]
Measurement of time in a specified range is not possible.
[Resolution]
Use measurement of time until execution stops.
No. 17 Regarding trace function(address supplement)
[Description]
Branch trace information being displayed consists of trace data on the branch origins and destinations and
complemented source code between the origins and destinations.
If the address of each branch origin has not been acquired, trace data may be indicated as invalid from the
beginning. Invalid data is displayed in the [Data] area.
[Resolution]
None
No. 18 Regarding trace function(setting of out-of-range trace event)
[Description]
For an out-of-range trace event, be sure to specify the start and end addresses.
[Resolution]
None
No. 19 Regarding trace function(section of out-of-range trace event)
[Description]
Only one section is specifiable for an out-of-range trace event.
[Resolution]
None
No. 20 Regarding trace function(abnormal exit of out-of-range trace event)
[Description]
After the emulator operation has been terminated by USB disconnection with an out-of-range trace event set,
re-connecting the emulator fails because the out-of-range trace event cannot be restored.
[Resolution]
None
No. 21 Regarding trace function(section trace/Range out trace)
[Description]
Concurrent use of “Section trace” and “Range Out trace” cannot be performed.
[Resolution]
None
R20UT2743EJ0200 Rev.2.00
Mar 20, 2014
Page 8 of 13