English
Language : 

HD404054 Datasheet, PDF (64/103 Pages) Hitachi Semiconductor – HMCS400-series microcomputers designed to increase program productivity with large-capacity memory
HD404054 Series/HD404094 Series
Notes on Use
When using the timer output as PWM output, note the following point. From the update of the timer write
register until the occurrence of the overflow interrupt, the PWM output differs from the period and duty
settings, as shown in table 24. The PWM output should therefore not be used until after the overflow
interrupt following the update of the timer write register. After the overflow, the PWM output will have the
set period and duty cycle.
Table 24 PWM Output Following Update of Timer Write Register
Mode
Free running
PWM Output
Timer Write Register is Updated during
High PWM Output
Timer write
register
updated to
value N
Interrupt
request
Timer Write Register is Updated during
Low PWM Output
Timer write
register
updated to
value N
Interrupt
request
Reload
T × (255 – N) T × (N + 1)
Timer write
register
updated to
value N
Interrupt
request
T × (N' + 1)
T × (255 – N) T × (N + 1)
Timer write
register
updated to
value N
Interrupt
request
T
T × (255 – N)
T
T
T × (255 – N)
T
62