HD74CDC2510B
Pin Function
Pin name
CLK
No.
24
Type
I
FBIN
13
I
G
FBOUT
1Y(0:9)
AVCC
11
I
12
O
3, 4, 5, 8, 9, O
15, 16, 17,
20, 21
23
Power
AGND
VCC
GND
1
Ground
2, 10, 14, 22 Power
6, 7, 18,19 Ground
Description
Clock input. CLK provides the clock signal to be distributed by the
HD74CDC2510B clock driver. CLK is used to provide the reference signal to
the integrated PLL that generates the clock output signals. CLK must have a
fixed frequency and fixed phase for the PLL to obtain phase lock. Once the
circuit is powered up and a valid CLK signal is applied, a stabilization time is
required for the PLL to phase lock the feedback signal to its reference signal.
Feedback input. FBIN provides the feedback signal to the internal PLL.
FBIN must be hard-wired to FBOUT to complete the PLL. The integrated
PLL synchronizes CLK and FBIN so that there is nominally zero phase error
between CLK and FBIN.
Output bank enable. G is the output enable for outputs 1Y(0:9). When G is
low, outputs 1Y(0:9)are disabled to a logic-low state. When G is high, all
outputs 1Y(0:9) are enabled and switch at the same frequency as CLK.
Feedback output. FBOUT is dedicated for external feedback. It switches at
the same frequency as CLK. When externally wired to FBIN, FBOUT
completes the feedback loop of the PLL.
Clock outputs. These outputs provide low-skew copies of CLK. Output bank
1Y(0:9) is enabled via the G input. These outputs can be disabled to a logic
low state by deasserting the G control input.
Analog power supply. AVCC provides the power reference for the analog
circuitry. In addition, AVCC can be used to bypass the PLL for test purposes.
When AVCC is strapped to ground, PLL is bypassed and CLK is buffered
directly to the device outputs.
Analog ground. AGND provides the ground reference for the analog
circuitry.
Power supply
Ground
Electrical Characteristics
Item
Symbol Min
Typ *1
Max
Unit
Test Conditions
Input clamp voltage
Output voltage
VIK
—
—
VOH
VCC–0.2
—
–1.2
—
V VCC = 3 V, II = –18 mA
V VCC = Min to Max, IOH = –100 µA
2.1
—
—
VCC = 3 V, IOH = –12 mA
2.4
—
—
VOL
—
—
0.2
VCC = 3 V, IOH = –6 mA
VCC = Min to Max, IOL = 100 µA
—
—
0.8
VCC = 3 V, IOL = 12 mA
—
Input current
IIN
—
Quiescent supply current
ICC
—
∆ICC
—
—
0.55
VCC = 3 V, IOL = 6 mA
—
±5
µA VCC = 3.6 V, VIN = VCC or GND
—
10
µA AVCC = GND, VCC = 3.6 V,
VI = VCC or GND, IO = 0
—
500
µA AVCC = GND, VCC = 3.3 to 3.6 V
One input at VCC–0.6 V,
Other inputs at VCC or GND
Input capacitance
CIN
—
4
—
pF VCC = 3.3 V, VI = VCC or GND
Output capacitance
CO
—
6
—
pF VCC = 3.3 V, VO = VCC or GND
Note: 1. For conditions shown as Min or Max, use the appropriate value specified under recommended operating
conditions.
Rev.9.00 Apr 07, 2006 page 4 of 7