English
Language : 

QB-78K0FX2-T44GB Datasheet, PDF (29/44 Pages) Renesas Technology Corp – IECUBE is a registered trademark of NEC Electronics Corporation in Japan and Germany PC/AT is a trademark of International Business Machines Corporation.
CHAPTER 2 SETUP PROCEDURE
(b) Connection of emulation probe GND wire
There are 2 GND wires in the emulation probe. Connect them to the QB-78K0FX2 and target system.
<1> Fasten the GND wire on the QB-78K0FX2 side of the emulation probe to the nut on the bottom of the
QB-78K0FX2 using a #0 or #1 Phillips precision driver (connection of B to A in Figure 2-6).
<2> Next plug the connector on top of the emulation probe into the connector at the opening on the bottom of
the QB-78K0FX2 from below being careful of the insertion direction.
Figure 2-6. GND Wire
QB-78K0FX2
A
B
C
Target system
<3> Connect the exchange adapter and emulation probe to the target connector.
<4> Connect the GND wire on the target system side of the emulation probe to the target system GND. If a
pin or screw is fastened to the target system GND, remove the transparent terminal cover on the end of
the GND wire and fasten the Y terminal of the GND wire to the target system (C in Figure 2-6). If the
GND on the target system is an exposed pad, likewise fasten the Y terminal to the pad on the target
system by soldering (recommended soldering iron temperature setting: 300°C).
User’s Manual U17669EJ3V0UM